CORC  > 北京大学  > 环境科学与工程学院
Performance of an Aerodyne Aerosol Mass Spectrometer (AMS) during Intensive Campaigns in China in the Summer of 2006
Takegawa, N. ; Miyakawa, T. ; Watanabe, M. ; Kondo, Y. ; Miyazaki, Y. ; Han, S. ; Zhao, Y. ; van Pinxteren, D. ; Bruggemann, E. ; Gnauk, T. ; Herrmann, H. ; Xiao, R. ; Deng, Z. ; Hu, M. ; Zhu, T. ; Zhang, Y.
刊名aerosol science and technology
2009
关键词BEAM WIDTH PROBE CHEMICAL-COMPOSITION FINE PARTICULATE AMBIENT AEROSOL INSTRUMENTS PARTICLES PHASE FIELD
DOI10.1080/02786820802582251
英文摘要An Aerodyne quadrupole aerosol mass spectrometer (AMS) was deployed in China in the summer of 2006. The measurements were made in the Pearl River Delta region in July 2006 (PRD campaign) and also in Beijing in August-September 2006 (CAREBEIJING campaign). The AMS successfully measured size-resolved chemical composition of submicron non-refractory aerosol (vaporized at 600C in vacuum) with a time resolution of 10 min, although some quantification issues have been identified. We observed extremely large signals at m/z 39 (39K+) and 41 (41K+), which significantly exceeded m/z 28 (N+2) signals. We also found large signals of m/z 85 (85Rb+), 87 (87Rb+), and 133 (Cs+). Laboratory experiments suggest that the large enhancement of K+ could have been due to the presence of K-containing particles in ambient air. The interferences of alkali metals at m/z 41, 85, 87, and 133 were significant and need to be corrected for better quantification of organic aerosol. The AMS measurements are compared with other, collocated measurements: a particle-into-liquid sampler combined with an ion chromatograph (PILS-IC), a Sunset Laboratory semi-continuous carbonaceous aerosol analyzer, and a Berner impactor sampler followed by off-line ion chromatography analysis (for major inorganic ions). We have found good agreement between the AMS and the other instruments when we assume an AMS particle collection efficiency (CE) of 0.5 for the PRD data and CE = 1.0 for the CAREBEIJING data. These results suggest that the AMS CE could be significantly different in different locations. Possible factors affecting the variability in the CE values are discussed.; Engineering, Chemical; Engineering, Mechanical; Environmental Sciences; Meteorology & Atmospheric Sciences; SCI(E); EI; 28; ARTICLE; 3; 189-204; 43
语种英语
内容类型期刊论文
源URL[http://ir.pku.edu.cn/handle/20.500.11897/246618]  
专题环境科学与工程学院
推荐引用方式
GB/T 7714
Takegawa, N.,Miyakawa, T.,Watanabe, M.,et al. Performance of an Aerodyne Aerosol Mass Spectrometer (AMS) during Intensive Campaigns in China in the Summer of 2006[J]. aerosol science and technology,2009.
APA Takegawa, N..,Miyakawa, T..,Watanabe, M..,Kondo, Y..,Miyazaki, Y..,...&Zhang, Y..(2009).Performance of an Aerodyne Aerosol Mass Spectrometer (AMS) during Intensive Campaigns in China in the Summer of 2006.aerosol science and technology.
MLA Takegawa, N.,et al."Performance of an Aerodyne Aerosol Mass Spectrometer (AMS) during Intensive Campaigns in China in the Summer of 2006".aerosol science and technology (2009).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace