CORC  > 北京大学  > 化学与分子工程学院
Improvement of the sensitivity of the two-dimensional asynchronous spectroscopy based on the AOSD approach by using a modified reference spectrum
Li, Xiaopei ; Bi, Quan ; Liu, Shaoxuan ; Chen, Jing ; Yue, Shijuan ; Wei, Yongju ; Huang, Kun ; Zhao, Ying ; Liu, Huizhou ; Zhai, Yanjun ; Xu, Yizhuang ; Noda, Isao ; Wu, Jinguang
刊名分子结构杂志
2013
关键词Two-dimensional asynchronous spectroscopy Intermolecular interaction Reference spectrum Sensitivity Signal-to-noise ratio PROBING INTERMOLECULAR INTERACTIONS INFRARED CORRELATION SPECTROSCOPY SAMPLE DESIGN SCHEME MOLECULAR RECOGNITION COMPONENT ANALYSIS FTIR SPECTROSCOPY IR SPECTROSCOPY COORDINATION MIXTURES BENZENE
DOI10.1016/j.molstruc.2012.08.050
英文摘要In this paper, a modified reference spectrum is utilized to generate 2D asynchronous spectra constructed by using the AOSD approach that is developed in our previous work. Mathematical analysis suggests that it is possible to enhance the intensity of cross peaks by using the modified reference spectrum. Computer simulation indicates that both intensity of cross peaks and signal-to-noise ratio of 2D spectra are improved significantly by adopting the modified reference spectrum. As a result, 2D asynchronous spectrum can be used to probe weak intermolecular interactions under the influence of spectral noise. Furthermore, experiments on acetonitrile/butanone/CCl4 system demonstrate that intensities and signal-to-noise ratio of cross peaks that reflect intermolecular interactions between acetonitrile and butanone can be enhanced remarkably by using the modified reference spectrum. (C) 2012 Elsevier B.V. All rights reserved.; http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000314554800015&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701 ; Chemistry, Physical; SCI(E); EI; 19; ARTICLE; 101-111; 1034
语种英语
内容类型期刊论文
源URL[http://ir.pku.edu.cn/handle/20.500.11897/150796]  
专题化学与分子工程学院
推荐引用方式
GB/T 7714
Li, Xiaopei,Bi, Quan,Liu, Shaoxuan,et al. Improvement of the sensitivity of the two-dimensional asynchronous spectroscopy based on the AOSD approach by using a modified reference spectrum[J]. 分子结构杂志,2013.
APA Li, Xiaopei.,Bi, Quan.,Liu, Shaoxuan.,Chen, Jing.,Yue, Shijuan.,...&Wu, Jinguang.(2013).Improvement of the sensitivity of the two-dimensional asynchronous spectroscopy based on the AOSD approach by using a modified reference spectrum.分子结构杂志.
MLA Li, Xiaopei,et al."Improvement of the sensitivity of the two-dimensional asynchronous spectroscopy based on the AOSD approach by using a modified reference spectrum".分子结构杂志 (2013).
个性服务
查看访问统计
相关权益政策