Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation Facility
Peng, P; Fu, J; Shi, XH; Yuan QX(袁清习); Huang WX(黄万霞); Yuan, QX; Huang, WX; Guo, W
刊名ANALYTICAL AND BIOANALYTICAL CHEMISTRY
2018
卷号410期号:27页码:7221-7228
关键词Synchrotron radiation X-ray Diffraction enhanced imaging Computed laminography Phase contrast imaging Dark-field imaging
ISSN号1618-2642
DOI10.1007/s00216-018-1329-7
文献子类Article
英文摘要Synchrotron radiation X-ray computed tomography (CT) enables nondestructive visualization of 3D morphological and chemical changes inside a sample and has become a powerful analysis tool to monitor reactive parts and their chemical states. However, synchrotron radiation CT imaging of specimens with lateral extensions much larger than the acceptance window of detectors is rather problematic due to strong absorption of X-rays in the lateral directions. On the other hand, X-ray computed laminography (CL) permits 3D imaging of flat samples while X-ray diffraction enhanced imaging (DEI) can provide high-quality results with different imaging contrasts such as absorption, phase and dark-field for samples with weak absorptions. Combining CL and DEI together, we have developed a multi-contrast DEI-CL system at the 4W1A beamline of the Beijing Synchrotron Radiation Facility for this kind of sample. Here we reported its design, implementation, and preliminary experimental results of carbon fiber reinforced polymer laminates with three kinds of imaging contrasts. The results have demonstrated the validity of this DEI-CL system. It will be helpful to push the applications of the state-of-the-art synchrotron radiation methods and instruments towards cutting-edge research.
电子版国际标准刊号1618-2650
WOS关键词X-RAY MICROSCOPY ; PHASE-CONTRAST ; CATALYST BODIES ; TALBOT INTERFEROMETRY ; TOMOGRAPHY ; NANOSCALE ; RECONSTRUCTION ; RADIOGRAPHY ; EVOLUTION ; CT
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
语种英语
WOS记录号WOS:000447361700025
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/286411]  
专题高能物理研究所_多学科研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Peng, P,Fu, J,Shi, XH,et al. Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation Facility[J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY,2018,410(27):7221-7228.
APA Peng, P.,Fu, J.,Shi, XH.,袁清习.,黄万霞.,...&Guo, W.(2018).Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation Facility.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,410(27),7221-7228.
MLA Peng, P,et al."Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation Facility".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 410.27(2018):7221-7228.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace