Status of the two-dimensional, multi-wire proportional chamber detector for the China Spallation Neutron Source | |
Qi, Huirong; Wen, Zhiwen; Qi HR(祁辉荣) | |
刊名 | International Journal of Modern Physics-Conference Series |
2018 | |
卷号 | 48页码:UNSP 1860121 |
关键词 | Multi-wire proportional chamber Position resolution |
ISSN号 | 2010-1945 |
DOI | 10.1142/s2010194518601217 |
文献子类 | Proceedings Paper |
英文摘要 | The re-designed two-dimensional, multi-wire proportional chamber (MWPC) detector based on the He-3 operation gas has been developed for the multifunctional reflection spectrum detection requirements in China Spallation Neutron Source (CSNS), which is under construction in Guangdong province, China. This efficient thermal neutron detector with large area (200 mm x 200 mm active area), two-dimensional position sensitive (<2 mm of position resolution), high detection efficiency (>65% in the wavelength of 1.8 angstrom) and good n/gamma discrimination would meet some requirements in CSNS. The neutron detector consists of a MWPC detector and a high-pressure gas vessel. The wire readout structures of the detector and the gas purity device have been optimized based on previous design and testing. The re-designed MWPC detector with an absorber thickness of 10 mm and 8.5 atm operating gas mixture of He-3 and C3H8 was constructed. Using the non-return valve manufactured by Swagelok, the gas purity device was developed to clean the water and remove gas impurities. The effective cycle time can be up to 50 min per sequence. The performance of the position resolution and the two-dimensional imaging accuracy by the traditional center of gravity readout method was studied with an X-ray radiation source and the neutron source. At the end of this year, the detector will be mounted at CSNS and studied using the neutron source. |
会议地点 | Crete, GREECE |
WOS研究方向 | Nuclear Science & Technology ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000460531300019 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihep.ac.cn/handle/311005/286735] |
专题 | 高能物理研究所_实验物理中心 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Qi, Huirong,Wen, Zhiwen,Qi HR. Status of the two-dimensional, multi-wire proportional chamber detector for the China Spallation Neutron Source[J]. International Journal of Modern Physics-Conference Series,2018,48:UNSP 1860121. |
APA | Qi, Huirong,Wen, Zhiwen,&祁辉荣.(2018).Status of the two-dimensional, multi-wire proportional chamber detector for the China Spallation Neutron Source.International Journal of Modern Physics-Conference Series,48,UNSP 1860121. |
MLA | Qi, Huirong,et al."Status of the two-dimensional, multi-wire proportional chamber detector for the China Spallation Neutron Source".International Journal of Modern Physics-Conference Series 48(2018):UNSP 1860121. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。