AC magnetic field measurement using a small flip coil system for rapid cycling AC magnets at the China Spallation Neutron Source (CSNS)
Li S(李帅); Liu YD(刘瑜冬); Liu YQ(刘艺琴); Xu SY(许守彦); Guo XL(郭晓玲); Wu X(吴锡); Deng CD(邓昌东); Li L(李藜); Wu YW(吴煜文); Wang S(王生)
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
2018
卷号880页码:80-86
关键词Small flip coil AC magnetic field measurement Dipole magnet Quadrupole magnet
ISSN号0168-9002
DOI10.1016/j.nima.2017.10.040
文献子类Article
英文摘要The China Spallation Neutron Source (CSNS) has two major accelerator systems, a linear accelerator and a rapid cycling synchrotron (RCS). The RCS accelerator is used to accumulate and accelerate protons from the energy of 80 MeV to the design energy of 1.6 GeV at the repetition rate of 25 Hz, and extract the high energy beam to the target. The main magnets of the RCS accelerator are excited by AC current with DC bias. The magnetic field quality is very important for the RCS accelerator operation, since it should guarantee and focus a circulating beam. In order to characterize the AC magnets, a small flip coil measurement system has been developed and one of each type of AC magnets has been studied. The measurement system and selected measurement results are presented in this paper. (c) 2017 Elsevier B.V. All rights reserved.
电子版国际标准刊号1872-9576
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics
语种英语
WOS记录号WOS:000418524200013
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/285509]  
专题高能物理研究所_加速器中心
通讯作者Zhou JX(周建新)
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Li S,Liu YD,Liu YQ,et al. AC magnetic field measurement using a small flip coil system for rapid cycling AC magnets at the China Spallation Neutron Source (CSNS)[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2018,880:80-86.
APA 李帅.,刘瑜冬.,刘艺琴.,许守彦.,郭晓玲.,...&周建新.(2018).AC magnetic field measurement using a small flip coil system for rapid cycling AC magnets at the China Spallation Neutron Source (CSNS).NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,880,80-86.