Optical Micro/Nanofiber-Based Localized Surface Plasmon Resonance Biosensors: Fiber Diameter Dependence | |
Zeng, Shuwen1; Zhou, Wenchao2; Li, Kaiwei3 | |
刊名 | SENSORS
![]() |
2018-10-01 | |
卷号 | 18期号:10页码:11 |
关键词 | localized surface plasmon resonance fiber optic biosensor optical micro/nanofiber |
ISSN号 | 1424-8220 |
DOI | 10.3390/s18103295 |
通讯作者 | Zhou, Wenchao(wczhou.ciomp.cas@gmail.com) ; Zeng, Shuwen(shuwen.zeng@unilim.fr) |
英文摘要 | Integration of functional nanomaterials with optical micro/nanofibers (OMNFs) can bring about novel optical properties and provide a versatile platform for various sensing applications. OMNFs as the key element, however, have seldom been investigated. Here, we focus on the optimization of fiber diameter by taking micro/nanofiber-based localized surface plasmon resonance sensors as a model. We systematically study the dependence of fiber diameter on the sensing performance of such sensors. Both theoretical and experimental results show that, by reducing fiber diameter, the refractive index sensitivity can be significantly increased. Then, we demonstrate the biosensing capability of the optimized sensor for streptavidin detection and achieve a detection limit of 1 pg/mL. Furthermore, the proposed theoretical model is applicable to other nanomaterials and OMNF-based sensing schemes for performance optimization. |
资助项目 | European Union[798916] |
WOS关键词 | GOLD NANOPARTICLES ; WAVE-GUIDES ; SENSOR ; SILICA ; ABSORPTION ; HYDROGEN ; TAPERS ; PROBE ; SIZE |
WOS研究方向 | Chemistry ; Electrochemistry ; Instruments & Instrumentation |
语种 | 英语 |
出版者 | MDPI |
WOS记录号 | WOS:000448661500123 |
资助机构 | European Union |
内容类型 | 期刊论文 |
源URL | [http://ir.ciomp.ac.cn/handle/181722/60292] ![]() |
专题 | 中国科学院长春光学精密机械与物理研究所 |
通讯作者 | Zeng, Shuwen; Zhou, Wenchao |
作者单位 | 1.Univ Limoges, XLIM Res Inst, CNRS, UMR 7252, F-87060 Limoges, France 2.Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, State Key Lab Appl Opt, Changchun 130033, Jilin, Peoples R China 3.Jinan Univ, Inst Photon Technol, Guangdong Key Lab Opt Fiber Sensing & Commun, Guangzhou 510632, Guangdong, Peoples R China |
推荐引用方式 GB/T 7714 | Zeng, Shuwen,Zhou, Wenchao,Li, Kaiwei. Optical Micro/Nanofiber-Based Localized Surface Plasmon Resonance Biosensors: Fiber Diameter Dependence[J]. SENSORS,2018,18(10):11. |