Mass Spectrometric Identification of Aliphatic Amines Using 2-[2-(7H-dibenzo[a,g]-carbazol-7-yl)-ethoxy] ethyl Chloroformate as Novel Fluorescence Labeling Reagent
Yan Tao ; Sun Xue-Jun ; Zhao Huai-Xin ; Sun Zhi-Wei ; Liu Qin-Ze ; Suo You-Rui ; You Jin-Mao
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY ; Yan, T; Sun, XJ; Zhao, HX; Sun, ZW; Liu, QZ; Suo, YR; You, JM.Mass Spectrometric Identification of Aliphatic Amines Using 2-[2-(7H-dibenzo[a,g]-carbazol-7-yl)-ethoxy] ethyl Chloroformate as Novel Fluorescence Labeling Reagent,CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2009,37(6):788-794
2009-06-01
英文摘要On a reversed-phase Eclipse XDB C8 ( 150 mm x 4.6 mm, 5 mu m) column, 12 aliphatic amine derivatives were derivatized using 2-[2-(7H-dibenzo[a, g] carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC-Cl) as a new pre-column derivatization reagent. The complete baseline resolution was obtained in conjunction with a gradient elution with acetonitrile/H(2)O as mobile phase. Detection was carried out by the fluorescence and online post-column atmospheric pressure chemical ionization(APCI) in positive-ion mode. The maximum excitation and emission wavelengths were at 300 nm and 400 nm, respectively. Identification of aliphatic amine derivatives was carried out by the online post-column Ion trap/mass spectrometry with positive-ion detection mode of APCI-MS. A rapid, accurate method for the determination of free aliphatic amine extracted from soil was proposed. The established method exhibited excellent reproducibility and recovery. Excellent linear responses were observed with the correlation coefficients > 0.9991. The detection limits( at signal-to-noise of 3:1) were 10.1-0.3 fmol.; On a reversed-phase Eclipse XDB C8 ( 150 mm x 4.6 mm, 5 mu m) column, 12 aliphatic amine derivatives were derivatized using 2-[2-(7H-dibenzo[a, g] carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC-Cl) as a new pre-column derivatization reagent. The complete baseline resolution was obtained in conjunction with a gradient elution with acetonitrile/H(2)O as mobile phase. Detection was carried out by the fluorescence and online post-column atmospheric pressure chemical ionization(APCI) in positive-ion mode. The maximum excitation and emission wavelengths were at 300 nm and 400 nm, respectively. Identification of aliphatic amine derivatives was carried out by the online post-column Ion trap/mass spectrometry with positive-ion detection mode of APCI-MS. A rapid, accurate method for the determination of free aliphatic amine extracted from soil was proposed. The established method exhibited excellent reproducibility and recovery. Excellent linear responses were observed with the correlation coefficients > 0.9991. The detection limits( at signal-to-noise of 3:1) were 10.1-0.3 fmol.
内容类型期刊论文
源URL[http://ir.nwipb.ac.cn//handle/363003/1864]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Yan Tao,Sun Xue-Jun,Zhao Huai-Xin,et al. Mass Spectrometric Identification of Aliphatic Amines Using 2-[2-(7H-dibenzo[a,g]-carbazol-7-yl)-ethoxy] ethyl Chloroformate as Novel Fluorescence Labeling Reagent[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, Yan, T; Sun, XJ; Zhao, HX; Sun, ZW; Liu, QZ; Suo, YR; You, JM.Mass Spectrometric Identification of Aliphatic Amines Using 2-[2-(7H-dibenzo[a,g]-carbazol-7-yl)-ethoxy] ethyl Chloroformate as Novel Fluorescence Labeling Reagent,CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2009,37(6):788-794,2009.
APA Yan Tao.,Sun Xue-Jun.,Zhao Huai-Xin.,Sun Zhi-Wei.,Liu Qin-Ze.,...&You Jin-Mao.(2009).Mass Spectrometric Identification of Aliphatic Amines Using 2-[2-(7H-dibenzo[a,g]-carbazol-7-yl)-ethoxy] ethyl Chloroformate as Novel Fluorescence Labeling Reagent.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY.
MLA Yan Tao,et al."Mass Spectrometric Identification of Aliphatic Amines Using 2-[2-(7H-dibenzo[a,g]-carbazol-7-yl)-ethoxy] ethyl Chloroformate as Novel Fluorescence Labeling Reagent".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY (2009).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace