Sensitive and accurate determination of neurotransmitters from in vivo rat brain microdialysate of Parkinson's disease using in situ ultrasound-assisted derivatization dispersive liquid-liquid microextraction by UHPLC-MS/MS
Zhao, Xian-En ; He, Yongrui ; Yan, Ping ; Wei, Na ; Wang, Renjun ; Sun, Jing ; Zheng, Longfang ; Zhu, Shuyun ; You, Jinmao
刊名RSC ADVANCES
2016
英文摘要A simple, rapid, sensitive and environmentally friendly ultrasound-assisted in situ derivatization dispersive liquid-liquid microextraction (in situ UA-DDLLME) method followed by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) has been developed for the simultaneous determination of amino acid neurotransmitters (AANTs) and monoamine neurotransmitters (MANTs) in rat brain microdialysates and baicalein in blood microdialysates of Parkinson's disease (PD) rats with in vivo multiple sites microdialysis in this work. A novel MS sensitive derivatization reagent 4'-carbonyl chloride rosamine (CCR) with a permanent positive charged moiety, has been designed, synthesized and reported for simultaneous labelling of amino and hydroxyl groups in neurotransmitters. Under the selected conditions, the derivatization and microextraction of analytes were simultaneously completed within 1.0 min. Good linearity for each analyte (R > 0.992) was observed with a low limit of detection (LOD, S/N > 3). Taken together, in situ UA-DDLLME coupled with UHPLC-MS/MS analysis was demonstrated to be a promising method for sensitive, accurate and simultaneous monitoring of AANTs and MANTs in rat brain and baicalein in rat blood. This method would be expected to be highly useful in PD clinical diagnostics and monitoring the efficacy of treatments.
内容类型期刊论文
源URL[http://ir.nwipb.ac.cn/handle/363003/6657]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Zhao, Xian-En,He, Yongrui,Yan, Ping,et al. Sensitive and accurate determination of neurotransmitters from in vivo rat brain microdialysate of Parkinson's disease using in situ ultrasound-assisted derivatization dispersive liquid-liquid microextraction by UHPLC-MS/MS[J]. RSC ADVANCES,2016.
APA Zhao, Xian-En.,He, Yongrui.,Yan, Ping.,Wei, Na.,Wang, Renjun.,...&You, Jinmao.(2016).Sensitive and accurate determination of neurotransmitters from in vivo rat brain microdialysate of Parkinson's disease using in situ ultrasound-assisted derivatization dispersive liquid-liquid microextraction by UHPLC-MS/MS.RSC ADVANCES.
MLA Zhao, Xian-En,et al."Sensitive and accurate determination of neurotransmitters from in vivo rat brain microdialysate of Parkinson's disease using in situ ultrasound-assisted derivatization dispersive liquid-liquid microextraction by UHPLC-MS/MS".RSC ADVANCES (2016).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace