CORC  > 中国科学院大学
Influence of acoustic pressure amplifier tube on a 300 hz thermoacoustically driven pulse tube cooler
Wang, Xiaotao1,2; Yu, Guoyao1; Dai, Wei1; Luo, Ercang1; Zhou, Yuan1
刊名Journal of applied physics
2010-10-01
卷号108期号:7页码:5
ISSN号0021-8979
DOI10.1063/1.3484046
通讯作者Wang, xiaotao()
英文摘要High frequency thermoacoustically driven pulse tube coolers (ptcs) have the advantages of high energy density, compact structure, and high reliability. through a series of improvements, the 300 hz thermoacoustically driven ptc in this paper achieved a fourfold increase in the cooling power compared with that in our last report. a cooling power of 1.04 w at 80 k and a no-load temperature of 63 k are obtained with 500 w heating power. in the system, the acoustic pressure amplifier tube (apat) plays an important role in coupling the thermoacoustic engine and the ptc. the effects of apat on the system performance are investigated here through both numeric simulations and experiments. the simulation indicates that length of the apat is limited due to impedance match requirement between the ptc and the engine, which is partly evidenced by experiments. calculation also gives a good agreement between calculated pressure wave amplification ratio and experimental values. apat with different lengths and diameters are investigated through experiments which indicate that there is an optimum diameter for the system performance. (c) 2010 american institute of physics. [doi:10.1063/1.3484046]
WOS关键词ENGINE
WOS研究方向Physics
WOS类目Physics, Applied
语种英语
出版者AMER INST PHYSICS
WOS记录号WOS:000283222200159
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2411528
专题中国科学院大学
通讯作者Wang, Xiaotao
作者单位1.Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
推荐引用方式
GB/T 7714
Wang, Xiaotao,Yu, Guoyao,Dai, Wei,et al. Influence of acoustic pressure amplifier tube on a 300 hz thermoacoustically driven pulse tube cooler[J]. Journal of applied physics,2010,108(7):5.
APA Wang, Xiaotao,Yu, Guoyao,Dai, Wei,Luo, Ercang,&Zhou, Yuan.(2010).Influence of acoustic pressure amplifier tube on a 300 hz thermoacoustically driven pulse tube cooler.Journal of applied physics,108(7),5.
MLA Wang, Xiaotao,et al."Influence of acoustic pressure amplifier tube on a 300 hz thermoacoustically driven pulse tube cooler".Journal of applied physics 108.7(2010):5.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace