A direct electrochemical method for diabetes diagnosis based on as-prepared boron-doped nanocrystalline diamond thin film electrodes | |
Zhao, Jianwen1; Wu, Daohong1; Zhi, Jinfang2,3 | |
刊名 | Journal of electroanalytical chemistry |
2009-02-15 | |
卷号 | 626期号:1-2页码:98-102 |
关键词 | Nonenzymatic sensor As-prepared bdnd thin film Blood glucose |
ISSN号 | 1572-6657 |
DOI | 10.1016/j.jelechem.2008.11.007 |
通讯作者 | Zhao, jianwen(zhjw76@hotmail.com) |
英文摘要 | The nonenzymatic glucose sensor based on as-prepared boron-doped nanocrystalline diamond (bdnd) thin film electrodes was developed and applied to measure blood glucose. the results show that the relationship between the peak current and the glucose concentration is linear in the range 2.5 x 10(-4) - 1.2 x 10(-2) m with a correlation coefficient of 0.992 in 0.2 m sodium hydroxide. different blood samples were measured by the nonenzymatic glucose sensor based on as-prepared bdnd thin film electrodes and the blood glucose monitoring system, respectively, and the measurement results obtained from the proposed method were basically similar to those of the commercial glucose device. the relative standard deviation (rsd) of the proposed method was less than 4.41%, and the recovery of blood samples ranged from 95.33% to 105.3%. additionally, the proposed method has some other advantages such as has high sensitivity, good reproducibility and stability. therefore the proposed method can be used to measure the blood glucose level with satisfactory results. crown copyright (c) 2008 published by elsevier b.v. all rights reserved. |
WOS关键词 | GLUCOSE DETECTION ; CARBON NANOTUBES ; SENSOR ; OXIDATION ; OXIDASE ; ENZYME ; FABRICATION ; PLATINUM ; ALKALINE |
WOS研究方向 | Chemistry ; Electrochemistry |
WOS类目 | Chemistry, Analytical ; Electrochemistry |
语种 | 英语 |
出版者 | ELSEVIER SCIENCE SA |
WOS记录号 | WOS:000263763500014 |
内容类型 | 期刊论文 |
URI标识 | http://www.corc.org.cn/handle/1471x/2405191 |
专题 | 中国科学院大学 |
通讯作者 | Zhao, Jianwen |
作者单位 | 1.Jishou Univ, Coll Chem & Chem Engn, Jishou 416000, Peoples R China 2.Chinese Acad Sci, Lab Organ Optoelect Funct Mat & Mol Engn, Tech Inst Phys & Chem, Beijing 100080, Peoples R China 3.Chinese Acad Sci, Grad Univ, Beijing 100080, Peoples R China |
推荐引用方式 GB/T 7714 | Zhao, Jianwen,Wu, Daohong,Zhi, Jinfang. A direct electrochemical method for diabetes diagnosis based on as-prepared boron-doped nanocrystalline diamond thin film electrodes[J]. Journal of electroanalytical chemistry,2009,626(1-2):98-102. |
APA | Zhao, Jianwen,Wu, Daohong,&Zhi, Jinfang.(2009).A direct electrochemical method for diabetes diagnosis based on as-prepared boron-doped nanocrystalline diamond thin film electrodes.Journal of electroanalytical chemistry,626(1-2),98-102. |
MLA | Zhao, Jianwen,et al."A direct electrochemical method for diabetes diagnosis based on as-prepared boron-doped nanocrystalline diamond thin film electrodes".Journal of electroanalytical chemistry 626.1-2(2009):98-102. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论