Simultaneous Determination of Multi-Organotin Compounds in Seawater by Liquid-Liquid Extraction-High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
Yu Zhen-hua2,3,4; Jing Miao1; Wang Xiao-ru1; Chen Deng-yun5; Huang Yan-liang2
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
2009-10-01
卷号29期号:10页码:2855-2859
关键词High Performance Liquid Chromatography-inductively Coupled Plasma Mass Spectrometry Organotin Compounds Speciation Analysis Seawater
ISSN号1000-0593
DOI10.3964/j.issn.1000-0593(2009)10-2855-05
文献子类Article
英文摘要The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds (trimethyltin, dibutyltin, tributyltin, diphenyltin and triphenyltin) in seawater samples. Agilent TC-C18 column was used for the separation, the mobile phase of HPLC was CH(3)CN : H(2)O: CH(3)COOH=65 : 23 : 12 (phi), 0.05% TEA, and pH value was adjusted to 3.0 by diluent ammonia. The flow rate was 0.6 mL . min(-1). Five mixed organotin compounds in a mix standard solution from 100 to 0.5 mu g . L(-1) were applied for the method assessment. The experimental results indicate that the correlation coefficient of calibration curves (R(2)) for each organotin compound was over 0.998 and the detection limits of the five organotin compounds were lower than 3 ng . L(-1). Different mixed organic solvents including dichloromethane or toluene were used for extraction of organotin and the extraction condition of organotin from seawater was optimized. The 100 mL seawater acidized by hydrochloric acid was extracted by 10 mL carbon dichloride (CH(2)Cl(2)) with 2% tropolone for 10 min twice. Extracted organic solvents were mixed And blown to one drop by nitrogen with the rate of 1.7 mL . min(-1), then 1 mL acetonitrile was added to the drop for redissolving the organotin compounds. Finally, the mixed redissolution was filtered by 0.22 mu m organic filter membrane before analysis. it was found that the only organotin compound in seawater was triphenyltin (TPHT) and the content was 53.2 ng . L(-1). The recoveries test from the standard addition for diphenyltin (DPHT), dibutyltin (DBT), tributyltin (TBT) and triphenyltin (TPHT) were over 80%. However, the recovery for trimethyltin (TMT) was relatively low and the value was 50%. The reason might be attributed to the decomposition or adsorption of those compounds during the extraction procedure. Further study on this subject is in progress.; The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds (trimethyltin, dibutyltin, tributyltin, diphenyltin and triphenyltin) in seawater samples. Agilent TC-C18 column was used for the separation, the mobile phase of HPLC was CH3CN : H2O: CH3COOH=65 : 23 : 12 (phi), 0.05% TEA, and pH value was adjusted to 3.0 by diluent ammonia. The flow rate was 0.6 mL . min(-1). Five mixed organotin compounds in a mix standard solution from 100 to 0.5 mu g . L-1 were applied for the method assessment. The experimental results indicate that the correlation coefficient of calibration curves (R-2) for each organotin compound was over 0.998 and the detection limits of the five organotin compounds were lower than 3 ng . L-1. Different mixed organic solvents including dichloromethane or toluene were used for extraction of organotin and the extraction condition of organotin from seawater was optimized. The 100 mL seawater acidized by hydrochloric acid was extracted by 10 mL carbon dichloride (CH2Cl2) with 2% tropolone for 10 min twice. Extracted organic solvents were mixed And blown to one drop by nitrogen with the rate of 1.7 mL . min(-1), then 1 mL acetonitrile was added to the drop for redissolving the organotin compounds. Finally, the mixed redissolution was filtered by 0.22 mu m organic filter membrane before analysis. it was found that the only organotin compound in seawater was triphenyltin (TPHT) and the content was 53.2 ng . L-1. The recoveries test from the standard addition for diphenyltin (DPHT), dibutyltin (DBT), tributyltin (TBT) and triphenyltin (TPHT) were over 80%. However, the recovery for trimethyltin (TMT) was relatively low and the value was 50%. The reason might be attributed to the decomposition or adsorption of those compounds during the extraction procedure. Further study on this subject is in progress.
学科主题Spectroscopy
URL标识查看原文
语种英语
WOS记录号WOS:000270346100062
公开日期2010-12-21
内容类型期刊论文
源URL[http://ir.qdio.ac.cn/handle/337002/2277]  
专题海洋研究所_海洋腐蚀与防护研究发展中心
作者单位1.First Inst Oceanog State Ocean Adm, Qingdao 266061, Peoples R China
2.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China
3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
4.Qingdao Ctr Dis & Prevent, Qingdao 266033, Peoples R China
5.Agilent Co China, Beijing 100022, Peoples R China
推荐引用方式
GB/T 7714
Yu Zhen-hua,Jing Miao,Wang Xiao-ru,et al. Simultaneous Determination of Multi-Organotin Compounds in Seawater by Liquid-Liquid Extraction-High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2009,29(10):2855-2859.
APA Yu Zhen-hua,Jing Miao,Wang Xiao-ru,Chen Deng-yun,&Huang Yan-liang.(2009).Simultaneous Determination of Multi-Organotin Compounds in Seawater by Liquid-Liquid Extraction-High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry.SPECTROSCOPY AND SPECTRAL ANALYSIS,29(10),2855-2859.
MLA Yu Zhen-hua,et al."Simultaneous Determination of Multi-Organotin Compounds in Seawater by Liquid-Liquid Extraction-High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry".SPECTROSCOPY AND SPECTRAL ANALYSIS 29.10(2009):2855-2859.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace