Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139 | |
Yao, S (Yao, Shuai)[ 1,2,3 ]; Lu, W (Lu, Wu)[ 1,2,4 ]![]() ![]() | |
刊名 | JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY
![]() |
2019 | |
卷号 | 56期号:2页码:172-178 |
关键词 | Enhanced low dose rate sensitivity single event transient bipolar voltage comparator synergistic effect |
ISSN号 | 0022-3131 |
DOI | 10.1080/00223131.2018.1539352 |
英文摘要 | The bipolar voltage comparator LM139 were exposed to ionizing radiation with a high-dose-rate of 10 rad(Si)/s and a low-dose-rate of 0.01 rad(Si)/s; then, pulsed laser single-event-transient (SET) testing was performed. The experimental results show that the SET phenomenon of LM139 after low-dose-rate irradiation of 0.01 rad(Si)/s is obviously different from the SET phenomenon of LM139 after high-dose-rate irradiation of 10 rad(Si)/s. After irradiation with the low-dose-rate, the comparator LM139 has Enhanced Low Dose Rate Sensitivity (ELDRS) in terms of the total dose effect, and the SET was further influenced by ELDRS. The greater gain degradation of the internal transistor in LM139 with low-dose-rate irradiation is the direct cause of this phenomenon. |
WOS记录号 | WOS:000455488700004 |
内容类型 | 期刊论文 |
源URL | [http://ir.xjipc.cas.cn/handle/365002/5666] ![]() |
专题 | 新疆理化技术研究所_中国科学院特殊环境功能材料与器件重点试验室 |
通讯作者 | Lu, W (Lu, Wu)[ 1,2,4 ] |
作者单位 | 1.Chinese Acad Sci, Key Lab Funct Mat & Devices Special Environm, Urumqi, Peoples R China 2.Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Urumqi, Peoples R China 3.Univ Chinese Acad Sci, Beijing, Peoples R China 4.Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China |
推荐引用方式 GB/T 7714 | Yao, S ,Lu, W ,Yu, X ,et al. Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139[J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY,2019,56(2):172-178. |
APA | Yao, S .,Lu, W .,Yu, X .,Wang, X .,Li, XL .,...&He, CF .(2019).Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139.JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY,56(2),172-178. |
MLA | Yao, S ,et al."Synergistic effect of enhanced low-dose-rate sensitivity and single event transient in bipolar voltage comparator LM139".JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY 56.2(2019):172-178. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论