Hybrid O-Space and FRONSAC Imaging | |
Haifeng Wang; Yuchou Chang; Dong Liang | |
2018 | |
会议日期 | 2018年 |
会议地点 | 巴黎 |
英文摘要 | Nonlinear spatial encoding magnetic (SEM) fields can accelerate data acquisitions and improve the imaging quality. In this work, the O-Space and FRONSAC imaging are combined into a hybrid nonlinear spatial encoding approach with dynamic nonlinear gradients. The preliminary experiment of phase mapping shows that the proposed method can be implemented in the current O-Space system. Simulations based on the preliminary experiment demonstrate that this approach can accelerate data acquisitions and reduce artefacts caused by highly undersampling acquisitions. |