Simultaneous removal of multiple odorants from source water suffering from septic and musty odors: Verification in a full-scale water treatment plant with ozonation
Guo, Qingyuan; Yang, Min; Zhang, Liping; Wen, Xiaodong; Wang, Chunmiao; Yu, Jianwei; Yang, Kai; Zhang, Dong; Xia, Ping
刊名WATER RESEARCH
2016-09-01
卷号100期号:0页码:1-6
关键词Odor (Odorant) Removal Ozonation Biological Activated Carbon (Bac) Odor Activity Value (Oav)
DOI10.1016/j.watres.2016.05.017
英文摘要Ozonation is known to be very effective in the removal of odorants from source water. However, it is not known if ozonation is effective in the removal of multiple odorants causing different types of odors. In this study, the removal performance for odors and odorants were evaluated in a Water Treatment Plant (WTP), which was equipped with coagulation, sedimentation, ozonation, biological activated carbon (BAC) filtration, sand filtration, and chlorination in succession and located in the downstream of the Huangpu (HP) River, over the period from April, 2014 to April, 2015. Flavor profile analysis (FPA) results showed that the source water was constantly associated with septic and musty odors. Geosmin and 2-MIB, with an average OAV of 4.54 and 138, respectively, were the major odorants for musty odor, while bis(2-chloroisopropyl) ether, DEDS and DMDS with an average OAV of 2.35, 1.65 and 0.78, respectively, might be responsible for the septic odor. While the musty odor could be removed effectively through the combination of ozonation and BAC, the septic odor and associated odorants required further treatment with sand filtration and chlorination for complete removal. It is clear that the advanced treatment process was effective for the treatment of source water containing complicated odorants. It should be noted that the sedimentation process needs careful management because release of odorants may occur during the treatment. The result of this study will be helpful for the mitigation of odors in WTP using source waters suffering from complicated odor problems. (C) 2016 Elsevier Ltd. All rights reserved.
内容类型期刊论文
源URL[http://ir.rcees.ac.cn/handle/311016/36211]  
专题生态环境研究中心_中国科学院饮用水科学与技术重点实验室
推荐引用方式
GB/T 7714
Guo, Qingyuan,Yang, Min,Zhang, Liping,et al. Simultaneous removal of multiple odorants from source water suffering from septic and musty odors: Verification in a full-scale water treatment plant with ozonation[J]. WATER RESEARCH,2016,100(0):1-6.
APA Guo, Qingyuan.,Yang, Min.,Zhang, Liping.,Wen, Xiaodong.,Wang, Chunmiao.,...&Xia, Ping.(2016).Simultaneous removal of multiple odorants from source water suffering from septic and musty odors: Verification in a full-scale water treatment plant with ozonation.WATER RESEARCH,100(0),1-6.
MLA Guo, Qingyuan,et al."Simultaneous removal of multiple odorants from source water suffering from septic and musty odors: Verification in a full-scale water treatment plant with ozonation".WATER RESEARCH 100.0(2016):1-6.