Immunosensor Interface Based on Physical and Chemical Immunogylobulin G Adsorption onto Mixed Self-Assembled Monolayers
Wang ZH(王战会); Viana AS; Jin G(靳刚); Abrantes LM
刊名Bioelectrochemistry
2006-10
通讯作者邮箱luisa.abrantes@fc.ul.pt
卷号69期号:2页码:180-186
关键词Mixed self-assembled monolayers Immunosensor Human immunoglobulin G Tween 20 Electrochemistry Ellipsometry
ISSN号1567-5394
通讯作者Abrantes, LM (reprint author), Univ Lisbon, Fac Ciencias, Lab SPM, Campo Grande, P-1749016 Lisbon, Portugal.
合作状况国际
中文摘要An immunosensor interface based on mixed hydrophobic self-assembled monolayers (SAMs) of methyl and carboxylic acid terminated thiols with covalently attached human Immunoglobulin G (hIgG), is investigated. The densely packed and organised SAMs were characterised by contact angle measurements and cyclic voltammetry. The effect of the non-ionic surfactant, Tween 20, in preventing nonspecific adsorption is addressed by ellipsometry during physical and covalent hIgG immobilization on pure and mixed SAMs, respectively. It is clearly demonstrated that nonspecific adsorption due to hydrophobic interactions of hIgG on methyl ended groups is totally inhibited, whereas electrostatic/hydrogen bonding interactions with the exposed carboxylic groups prevail in the presence of surfactant. Results of ellipsometry and Atomic Force Microscopy, reveal that the surface concentration of covalently immobilized hIgG is determined by the ratio of COOH/CH3-terminated thiols in SAM forming solution. Moreover, the ellipsometric data demonstrates that the ratio of bound anti-hIgG/hIgG depends on the density of hIgG on the surface and that the highest ratio is close to three. We also report the selectivity and high sensitivity achieved by chronoamperometry in the detection of adsorbed hIgG and the reaction with its antibody.
学科主题力学
类目[WOS]Biochemistry & Molecular Biology ; Biology ; Biophysics ; Electrochemistry
研究领域[WOS]Biochemistry & Molecular Biology ; Life Sciences & Biomedicine - Other Topics ; Biophysics ; Electrochemistry
关键词[WOS]SURFACE-PLASMON RESONANCE ; SCANNING FORCE MICROSCOPY ; PROTEIN ADSORPTION ; ALKANETHIOLATE MONOLAYERS ; POLY(ETHYLENE GLYCOL) ; REDUCTIVE DESORPTION ; GOLD ELECTRODES ; MODEL SURFACES ; IMMOBILIZATION ; ANTIBODY
收录类别SCI
原文出处http://dx.doi.org/10.1016/j.bioelechem.2006.02.001
语种英语
WOS记录号WOS:000242005800007
公开日期2007-06-15 ; 2007-12-05 ; 2009-06-23
内容类型期刊论文
源URL[http://dspace.imech.ac.cn/handle/311007/17676]  
专题力学研究所_力学所知识产出(1956-2008)
推荐引用方式
GB/T 7714
Wang ZH,Viana AS,Jin G,et al. Immunosensor Interface Based on Physical and Chemical Immunogylobulin G Adsorption onto Mixed Self-Assembled Monolayers[J]. Bioelectrochemistry,2006,69(2):180-186.
APA Wang ZH,Viana AS,Jin G,&Abrantes LM.(2006).Immunosensor Interface Based on Physical and Chemical Immunogylobulin G Adsorption onto Mixed Self-Assembled Monolayers.Bioelectrochemistry,69(2),180-186.
MLA Wang ZH,et al."Immunosensor Interface Based on Physical and Chemical Immunogylobulin G Adsorption onto Mixed Self-Assembled Monolayers".Bioelectrochemistry 69.2(2006):180-186.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace