lolite Based Bulk Normalization as 100% (m/m) Quantification Strategy for Reduction of Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Transient Signal
Wu Shi-Tou1,2,3; Huang Chao1,2; Xie Lie-Wen1,2; Yang Yue-Heng1,2; Yang Jin-Hui1,2
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
2018-10-01
卷号46期号:10页码:1628-1635
关键词Laser ablation-inductively coupled plasma-mass spectrometry Iolite package Bulk normalization as 100% (m/m) Combined uncertainty CGSG reference material
ISSN号0253-3820
DOI10.1016/S1872-2040(18)61118-1
英文摘要Iolite package draw more attention in laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) community in recent years due to its powerful data-handling capacity, excellent signal visualization and open source of calculation codes. In this study, the application of Iolite package was investigated for LA-ICP-MS elemental quantification, and a calculation code for the bulk normalization as 100% (m/m) strategy was compiled. We found that the spline interpolation approach was better than that of linear one for the correction of time-dependent instrument drift. BCR-2G as the quality material was used to assess the proposed code, and the results revealed that the code was practical and reliable. The analytical accuracy was influenced by the used calibration materials. TiO2, MgO, K2O and rare earth elements in BCR-2G were slightly off (5%-10%) when NIST SRM 610 as the calibrator. Cr and Mo were higher (10%-30%) than the recommended values when StHs6/80-G was used as the calibrator. The phenomena would be attributed to the matrix effect or the inaccurate values of corresponding calibrators. Three main sources for the LA-ICP-MS combined uncertainty were recognized, including the uncertainty of recommended values of analytes in calibration material, the uncertainty of measured intensity ratios in sample and the error in bulk normalization as 100% (m/m) strategy. A total of 50 elements in CGSG glass reference materials were quantified based on the proposed Iolite code. Major elements (except MnO, CaO and P2O5) matched well with the recommended values with a discrepancy of 5%, and the trace elements (except Cr, Ni, Zn, Ga, Mo and Sb) were agreement with the recommended values in 10%. The dataset reported in this study was helpful for the value certification of CGSG reference materials. Overall, the proposed Iolite code broadened the application of Iolite package in the reduction of LA-ICP-MS transient signal for the elemental determination.
资助项目National Natural Science Foundation of China[41525012] ; China Scholarship Council[201306410007]
WOS关键词U-PB ; ICP-MS ; QUANTITATIVE-ANALYSIS ; IOLITE FREEWARE ; TRACE-ELEMENTS ; ZIRCON ; MINERALS
WOS研究方向Chemistry
语种英语
出版者ELSEVIER SCIENCE INC
WOS记录号WOS:000451326500008
资助机构National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; National Natural Science Foundation of China ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council ; China Scholarship Council
内容类型期刊论文
源URL[http://ir.iggcas.ac.cn/handle/132A11/89601]  
专题地质与地球物理研究所_岩石圈演化国家重点实验室
通讯作者Wu Shi-Tou
作者单位1.Chinese Acad Sci, Inst Geol & Geophys, State Key Lab Lithospher Evolut, Beijing 100029, Peoples R China
2.Chinese Acad Sci, Inst Earth Sci, Beijing 100029, Peoples R China
3.Gottingen Univ, Fac Geol & Geophys, D-37077 Gottingen, Germany
推荐引用方式
GB/T 7714
Wu Shi-Tou,Huang Chao,Xie Lie-Wen,et al. lolite Based Bulk Normalization as 100% (m/m) Quantification Strategy for Reduction of Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Transient Signal[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2018,46(10):1628-1635.
APA Wu Shi-Tou,Huang Chao,Xie Lie-Wen,Yang Yue-Heng,&Yang Jin-Hui.(2018).lolite Based Bulk Normalization as 100% (m/m) Quantification Strategy for Reduction of Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Transient Signal.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,46(10),1628-1635.
MLA Wu Shi-Tou,et al."lolite Based Bulk Normalization as 100% (m/m) Quantification Strategy for Reduction of Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Transient Signal".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 46.10(2018):1628-1635.