Hydrostatic support system for in-situ optical testing of a 4 m aperture SiC mirror
Hu, H.-F.; H.-W. Zhao; Z.-Y. Liu; X. Luo and X.-J. Zhang
刊名Guangxue Jingmi Gongcheng/Optics and Precision Engineering
2017
卷号25期号:10
英文摘要A set of hydrostatic support system for a 4 m SiC mirror in-situ testing was designed to reduce the risk of ultra-large mirror off-line testing and to improve fabrication efficiency. Firstly, the analytical formula for calculating support stiffness was derived, and its main factor was found. Then, some support samples were tested, and the support stiffness of a single support unit in different groups was predicted by combining the sample results and analytical formula. Finally, the stability of the support system was evaluated by pressurization test and in-situ testing, and the mirror surface precision with its gravity offloaded by the support system was calculated by finite element simulation. Results show that the average stiffness is about 1.9 kN/mm with a relative difference among support units about 3% when 5 units are linked together, the stiffness for a single unit isolated is as high as 15 kN/mm, and 3 kinds of unit stiffness in the support system are 1.7, 1.1 and 0.8 kN/mm respectively. Moreover, pressurization test shows a slow pressure change, which indicates that the system is well sealed. When the hydrostatic system was used for a 4 m mirror, the height changes rise up and down within 50 m in 11 days, and the relative change is less than 20 m. When the mirror is supported on 54 units with stiffness difference by 3% randomly, the surface RMS is less than 20 nm. The proposed system meets the requirement of in-situ optical testing for precision and stability. 2017, Science Press. All right reserved.
语种中文
内容类型期刊论文
源URL[http://ir.ciomp.ac.cn/handle/181722/58944]  
专题长春光学精密机械与物理研究所_中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Hu, H.-F.,H.-W. Zhao,Z.-Y. Liu,et al. Hydrostatic support system for in-situ optical testing of a 4 m aperture SiC mirror[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2017,25(10).
APA Hu, H.-F.,H.-W. Zhao,Z.-Y. Liu,&X. Luo and X.-J. Zhang.(2017).Hydrostatic support system for in-situ optical testing of a 4 m aperture SiC mirror.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,25(10).
MLA Hu, H.-F.,et al."Hydrostatic support system for in-situ optical testing of a 4 m aperture SiC mirror".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 25.10(2017).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace