Tuner control system of Spoke012 SRF cavity for C-ADS injector I
Liu N(刘娜); Sun Y(孙毅); Wang GW(王光伟); Mi ZH(米正辉); Lin HY(林海英); Wang QY(王群要); Liu R(刘熔); Ma XP(马新朋); Liu, N; Sun, Y
刊名CHINESE PHYSICS C
2016
卷号40期号:9
关键词tuner control spoke cavity PLC
DOI10.1088/1674-1137/40/9/097001
通讯作者刘娜
文献子类Article
英文摘要A new tuner control system for spoke superconducting radio frequency (SRF) cavities has been developed and applied to cryomodule I of the C-ADS injector I at the Institute of High Energy Physics, Chinese Academy of Sciences. We have successfully implemented the tuner controller based on Programmable Logic Controller (PLC) for the first time and achieved a cavity tuning phase error of +/- 0.7 degrees (about +/- 4 Hz peak to peak) in the presence of electromechanical coupled resonance. This paper presents preliminary experimental results based on the PLC tuner controller under proton beam commissioning.
语种英语