Longitudinal Jitter Analysis of a Linear Accelerator Electron Gun
Liu MS(刘明善); Iqbal, M; Liu, M
刊名Applied Sciences-Basel
2016
卷号6期号:11
关键词gun trigger timing longitudinal jitter beam performance PARMELA
DOI10.3390/app6110350
通讯作者Munawar Iqbal
英文摘要We present measurements and analysis of the longitudinal timing jitter of a Beijing Electron Positron Collider (BEPCII) linear accelerator electron gun. We simulated the longitudinal jitter effect of the gun using PARMELA to evaluate beam performance, including: beam profile, average energy, energy spread, and XY emittances. The maximum percentage difference of the beam parameters is calculated to be 100%, 13.27%, 42.24% and 65.01%, 86.81%, respectively. Due to this, the bunching efficiency is reduced to 54%. However, the longitudinal phase difference of the reference particle was 9.89 degrees . The simulation results are in agreement with tests and are helpful to optimize the beam parameters by tuning the trigger timing of the gun during the bunching process.
语种英语
WOS记录号WOS:000389532800040
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/260580]  
专题高能物理研究所_加速器中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Liu MS,Iqbal, M,Liu, M. Longitudinal Jitter Analysis of a Linear Accelerator Electron Gun[J]. Applied Sciences-Basel,2016,6(11).
APA 刘明善,Iqbal, M,&Liu, M.(2016).Longitudinal Jitter Analysis of a Linear Accelerator Electron Gun.Applied Sciences-Basel,6(11).
MLA 刘明善,et al."Longitudinal Jitter Analysis of a Linear Accelerator Electron Gun".Applied Sciences-Basel 6.11(2016).