Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review
Yu HL(于海龙); Wang HW(王洪伟); Zhao YW(赵忆文); Mo, Zhongjun; Xiang LB(项良碧); Zhou Y(周跃); Li CQ(李长青); Han JD(韩建达); Chen Y(陈语); Liu J(刘军)
刊名CLINICS
2017
卷号72期号:10页码:609-617
关键词Biomechanics Finite Element Analysis Spine Fracture Monoaxial Pedicle Screw Polyaxial Pedicle Screw
ISSN号1807-5932
通讯作者Wang HW(王洪伟)
产权排序1
中文摘要OBJECTIVES: No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS: Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, largest maximal von Mises stress of the instrumentation, and intradiscal pressures of the adjacent segment under displacement loading were evaluated. Radiographic results of 230 patients with traumatic thoracolumbar fractures treated with these fixations were reviewed, and the sagittal Cobb's angle, vertebral body angle, anterior vertebral body height of the fractured vertebrae and adjacent segment degeneration were calculated and evaluated. RESULTS: The largest maximal values of the von Mises stress were 376.8 MPa for the pedicle screws in the short-segment monoaxial pedicle screw fixation model and 439.9 MPa for the rods in the intermediate monoaxial pedicle screw fixation model. The maximal intradiscal pressures of the upper adjacent segments were all greater than those of the lower adjacent segments. The maximal intradiscal pressures of the monoaxial pedicle screw fixation model were larger than those in the corresponding segments of the normal model. The radiographic results at the final follow-up evaluation showed that the mean loss of correction of the sagittal Cobb's angle, vertebral body angle and anterior vertebral body height were smallest in the intermediate monoaxial pedicle screw fixation group. Adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group but more likely to be observed in the intermediate monoaxial pedicle screw fixation group. CONCLUSION: Smaller von Mises stress in the pedicle screws and lower intradiscal pressure in the adjacent segment were observed in the polyaxial screw model than in the monoaxial pedicle screw fixation spine models. Fracture-level fixation could significantly correct kyphosis and reduce correction loss, and adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group.
WOS标题词Science & Technology ; Life Sciences & Biomedicine
类目[WOS]Medicine, General & Internal
研究领域[WOS]General & Internal Medicine
关键词[WOS]LUMBAR INTERBODY FUSION ; ADJACENT DISC DEGENERATION ; BURST FRACTURES ; SPINAL-FUSION ; EARLY FAILURE ; FOLLOW-UP ; INSTRUMENTATION ; LEVEL ; EFFICACY ; DISEASE
收录类别SCI
语种英语
WOS记录号WOS:000415369400004
内容类型期刊论文
源URL[http://ir.sia.cn/handle/173321/21227]  
专题沈阳自动化研究所_机器人学研究室
作者单位1.Department of Orthopedics, Xinqiao Hospital, the Third Military Medical University, Chongqing, 400037, China.
2.Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Shenyang, Liaoning, 110016, China
3.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Science, Shenyang, Liaoning, 110016, China
4.National Research Center for Rehabilitation Aids, Beijing, 100176, China
推荐引用方式
GB/T 7714
Yu HL,Wang HW,Zhao YW,et al. Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review[J]. CLINICS,2017,72(10):609-617.
APA Yu HL.,Wang HW.,Zhao YW.,Mo, Zhongjun.,Xiang LB.,...&Wang Q.(2017).Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review.CLINICS,72(10),609-617.
MLA Yu HL,et al."Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review".CLINICS 72.10(2017):609-617.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace