Method of realizing compact Fourier transform spectrometer without moving parts based on birefringent liquid crystal | |
Xia, Liangping1,2; Yang, Zheng2![]() ![]() ![]() | |
刊名 | OPTICAL ENGINEERING
![]() |
2014-07-01 | |
卷号 | 53期号:7页码:4 |
关键词 | Fourier transform spectrometer birefringent liquid crystal interference miniaturization |
ISSN号 | 0091-3286 |
DOI | 10.1117/1.OE.53.7.074109 |
通讯作者 | Du, CL (reprint author), Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Key Lab Multiscale Mfg Technol, Chongqing 400714, Peoples R China. |
英文摘要 | A method of realizing a compact Fourier transform spectrometer is proposed in this work, which is based on the polarization interference in a single layer of birefringent liquid crystal (BLC). The continuous interference between the ordinary light and the extraordinary light is driven by a continuously adjusted electric field. Benefiting from the single-layer configuration with no moving parts, the spectrometer is easily miniaturized. The method to realize the spectrometer is theoretically analyzed and experimentally demonstrated by a layer of nematic BLC with a 100-mu m thickness. (c) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
资助项目 | Graduate Student Innovation Foundation of Institute of Optics and Electronics, Chinese Academy of Sciences ; National Natural Science Foundation of China[11174281] ; National Natural Science Foundation of China[61275061] ; West Light Foundation of Chinese Academy of Sciences ; Application Development Project of Chongqing[cstc2013yykfC00007] ; Fundamental and Advanced Research Projects of Chongqing[cstc2013jcyjC00001] |
WOS研究方向 | Optics |
语种 | 英语 |
出版者 | SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS |
WOS记录号 | WOS:000341183900036 |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.138/handle/2HOD01W0/769] ![]() |
专题 | 集成光电技术研究中心 微纳制造与系统集成研究中心 |
通讯作者 | Du, Chunlei |
作者单位 | 1.Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China 2.Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Key Lab Multiscale Mfg Technol, Chongqing 400714, Peoples R China |
推荐引用方式 GB/T 7714 | Xia, Liangping,Yang, Zheng,Yin, Shaoyun,et al. Method of realizing compact Fourier transform spectrometer without moving parts based on birefringent liquid crystal[J]. OPTICAL ENGINEERING,2014,53(7):4. |
APA | Xia, Liangping,Yang, Zheng,Yin, Shaoyun,Deng, Qiling,&Du, Chunlei.(2014).Method of realizing compact Fourier transform spectrometer without moving parts based on birefringent liquid crystal.OPTICAL ENGINEERING,53(7),4. |
MLA | Xia, Liangping,et al."Method of realizing compact Fourier transform spectrometer without moving parts based on birefringent liquid crystal".OPTICAL ENGINEERING 53.7(2014):4. |