Design of coolant distribution system (CDS) for ITER PF AC/DC converter | |
Guo, Bin1; Song, Zhiquan1; Fu, Peng1; Xu, Xuesong1; Li, Chuan1; Wang, Min2; Dong, Lin2 | |
刊名 | FUSION ENGINEERING AND DESIGN |
2016-10-01 | |
卷号 | 108期号:无页码:21-27 |
关键词 | Coolant Distribution System Design Thermal-hydraulic Ac/dc Converter |
DOI | 10.1016/j.fusengdes.2016.04.027 |
文献子类 | Article |
英文摘要 | The Poloidal Field (PF) converter unit, playing an essential role in the plasma shape and position control in vertical and horizontal direction, which is an important part of ITER power supply system. As an important subsystem of the converter unit, the coolant distribution system has the function to distribute the cooling water from ITER component cooling water system (CCWS) to its main components at the required flow rate, pressure and temperature. This paper presents the thermal hydraulic design of coolant distribution system for the ITER PF converter unit. Different operational requirements of the PF converter unit regarding flow rate, temperature and pressure have been analyzed to design the system process and arrangement. A thermal-hydraulic analysis model has been built to size the system and predict the flow rate and temperature distribution of the system under the normal operation. Based on the system thermal-hydraulic analysis results, the system pressure profile has been plotted to evaluate the pressure behavior along each client flow path. A CDS prototype for the ITER PF converter has been constructed and some experiments have been performed on it. A good agreement of the flow distribution and temperature behavior between the simulated and test results validate the proposed design methodology. (C) 2016 Elsevier B.V. All rights reserved. |
WOS研究方向 | Nuclear Science & Technology |
语种 | 英语 |
WOS记录号 | WOS:000377736500003 |
内容类型 | 期刊论文 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/21718] |
专题 | 合肥物质科学研究院_中科院等离子体物理研究所 |
作者单位 | 1.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China 2.China Int Nucl Fus Energy Program Execut Ctr, Beijing 100862, Peoples R China |
推荐引用方式 GB/T 7714 | Guo, Bin,Song, Zhiquan,Fu, Peng,et al. Design of coolant distribution system (CDS) for ITER PF AC/DC converter[J]. FUSION ENGINEERING AND DESIGN,2016,108(无):21-27. |
APA | Guo, Bin.,Song, Zhiquan.,Fu, Peng.,Xu, Xuesong.,Li, Chuan.,...&Dong, Lin.(2016).Design of coolant distribution system (CDS) for ITER PF AC/DC converter.FUSION ENGINEERING AND DESIGN,108(无),21-27. |
MLA | Guo, Bin,et al."Design of coolant distribution system (CDS) for ITER PF AC/DC converter".FUSION ENGINEERING AND DESIGN 108.无(2016):21-27. |