CORC  > 国家天文台  > 中国科学院国家天文台  > 射电天文研究部
Ultra-low loss lumped element cryogenic coolable high pass filter and cryogenic measurement method
Liu, Hongfei1,2; Weinreb, Sander3
刊名MICROWAVE AND OPTICAL TECHNOLOGY LETTERS
2017-09-01
卷号59期号:9页码:2229-2235
关键词high pass filter ultra-low loss cryogenic cooling cryogenic measurement
英文摘要This letter presents an ultra-low loss cryogenically-coolable lumped element high pass filter and the measurement method of its S parameters and noise temperature at cryogenic temperature. This filter is going to be used in RFI mitigation of FAST wideband single pixel receiver. It adopts 5 poles Chebyshev high pass structure, and ultra-low loss lumped elements are employed. At cryogenic temperature, its 3 dB cutoff frequency is 248 MHz and the high-end of passband with ultra-low insertion loss is up to 3.5 GHz. Specially, the novel mechanical and microwave design ensure effectively cryogenic cooling to all components of the filter. This filter can be operated at temperatures of 300-4 K. S parameters are measured at room and cryogenic temperatures. At 26 K, its insertion loss in passband is smaller than 0.1 dB. A direct measurement to noise temperature at 24 K physical temperature is performed in cryogenic Testing Dewar, and noise temperature smaller than 0.55 K is achieved. The stopband rejection at 95 MHz is larger than 43 dB. In passband, the return loss of 2 ports is larger than 23 dB.
WOS标题词Science & Technology ; Technology ; Physical Sciences
类目[WOS]Engineering, Electrical & Electronic ; Optics
研究领域[WOS]Engineering ; Optics
收录类别SCI
语种英语
WOS记录号WOS:000404366000024
内容类型期刊论文
源URL[http://ir.bao.ac.cn/handle/114a11/8819]  
专题国家天文台_射电天文研究部
作者单位1.Chinese Acad Sci, Natl Astron Observ, Beijing 100012, Peoples R China
2.Chinese Acad Sci, Key Lab Radio Astron, Nanjing 21008, Jiangsu, Peoples R China
3.CALTECH, Pasadena, CA 91125 USA
推荐引用方式
GB/T 7714
Liu, Hongfei,Weinreb, Sander. Ultra-low loss lumped element cryogenic coolable high pass filter and cryogenic measurement method[J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS,2017,59(9):2229-2235.
APA Liu, Hongfei,&Weinreb, Sander.(2017).Ultra-low loss lumped element cryogenic coolable high pass filter and cryogenic measurement method.MICROWAVE AND OPTICAL TECHNOLOGY LETTERS,59(9),2229-2235.
MLA Liu, Hongfei,et al."Ultra-low loss lumped element cryogenic coolable high pass filter and cryogenic measurement method".MICROWAVE AND OPTICAL TECHNOLOGY LETTERS 59.9(2017):2229-2235.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace