CORC  > 厦门大学  > 环境生态-已发表论文
Loop flow analysis of dissolved reactive phosphorus in aqueous samples
Ma, Jian ; Li, Quanlong ; Yuan, Dongxing ; Ma J(马剑) ; Li QL(李权龙) ; Yuan DX(袁东星)
刊名http://dx.doi.org/10.1016/j.talanta.2014.02.020
2014
关键词PHOSPHOANTIMONYLMOLYBDENUM BLUE COMPLEX INJECTION-ANALYSIS ESTUARINE WATERS NANOMOLAR CONCENTRATIONS PHOSPHATE NUTRIENTS SEAWATER REEXAMINATION ANALYZER CELL
英文摘要National Science Foundation of China [41306090]; Fundamental Research Funds for the Central Universities [2012121062]; The current flow based method for the determination of dissolved reactive phosphorus (DRP) suffers interference from salinity (e.g. index refractive difference) and the incidentally formed bubbles, which can be a problem for optical detection. Here we reported a simple and robust loop flow analysis (LFA) method for accurate measurement of DRP in different aqueous samples. The chemistry is based on the classic phosphomolybdenum blue (PMB) reaction and the PMB formed in a novel cross-shaped flow cell was detected at 700 nm using a miniature spectrophotometer. The effects of reagents on the kinetic formation of PMB were evaluated. The detection limit was 32 nM with an optical pathlength of 1 cm and the relative standard deviations for repetitive determinations of 1, 2 and 8 mu M phosphate solutions were 1.8% (n=113, without any stoppage during repeating analysis for > 7 h), 1.0% (n=49) and 0.39% (n=9), respectively. The analysis time was 4 min sample(-1). The effects of salinity and interfering ions (silicate and arsenate) were evaluated and showed no interference under the proposed protocol for DRP analysis. Using the LFA method, different aqueous samples with a salinity range of 0-34 were analyzed and the results showed excellent agreement with the reference method (slope 0.9982 +/- 0.0063, R-2=0.9987, n=34). Recoveries for spiked samples varied from 95.4% to 103.7%. The proposed method showed insignificant interference from salinity, silicate and arsenate, higher reproducibility, easier operation and was free of the bubble problem. (C) 2014 Elsevier B.V. All rights reserved.
语种英语
出版者ELSEVIER SCIENCE BV
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/89939]  
专题环境生态-已发表论文
推荐引用方式
GB/T 7714
Ma, Jian,Li, Quanlong,Yuan, Dongxing,et al. Loop flow analysis of dissolved reactive phosphorus in aqueous samples[J]. http://dx.doi.org/10.1016/j.talanta.2014.02.020,2014.
APA Ma, Jian,Li, Quanlong,Yuan, Dongxing,马剑,李权龙,&袁东星.(2014).Loop flow analysis of dissolved reactive phosphorus in aqueous samples.http://dx.doi.org/10.1016/j.talanta.2014.02.020.
MLA Ma, Jian,et al."Loop flow analysis of dissolved reactive phosphorus in aqueous samples".http://dx.doi.org/10.1016/j.talanta.2014.02.020 (2014).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace