CORC  > 厦门大学  > 化学化工-已发表论文
Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide
Wu, Geng-huang ; Song, Xin-hong ; Wu, Yan-fan ; Chen, Xiao-mei ; Luo, Feng ; Chen, Xi ; Chen X(陈曦)
刊名http://dx.doi.org/10.1016/j.talanta.2012.10.066
2013
关键词CARBON NANOTUBES ELECTROCATALYTIC OXIDATION METHANOL OXIDATION GRAPHITE OXIDE ELECTRODE CATALYSTS HYDROGEN NANOCOMPOSITE NANOPARTICLES ELECTROOXIDATION
英文摘要National Natural Science Foundation of China [21175112]; NFFTBS [J1030415]; A non-enzymatic electrochemical method was developed for glucose detection using a glassy carbon electrode modified with platinum nanoflowers supported on graphene oxide (PtNFs-GO). PtNFs-GO was synthesized using a nontoxic, rapid, one-pot and template-free method. Low-cost, green solvent ethanol acted as the reductant, and the advanced and effective 2D carbon material-GO nanosheet acted as the stabilizing material. Their morphologies were characterized using transmission electron microscopy. Cyclic voltammetry and amperometric methods were used to evaluate the electrocatalytic activity towards glucose in neutral media. The modified electrode exhibited strong and sensitive amperometric responses to glucose even in the presence of a high concentration of chloride ions. The response time was within 5 s. The interference effects from ascorbic acid and uric acid were comparatively small when operated at suitable potential. Under optimal detection potential (0.47 V with a saturated calomel reference electrode) the PtNFs-GO modified electrode performed a current response towards glucose at a broad concentration range from 2 mu M to 20.3 mM. Two linear regions could be observed at 2 mu M to 10.3 mM with a sensitivity of 1.26 mu A mM(-1) cm(-2) (correlation coefficient 0.9968), and at 10.3 mM to 20.3 mM with a sensitivity of 0.64 mu A mM(-1) cm(-2)(correlation coefficient 0.9969). The LOD of 2 mu M was lower than many non-enzymatic electrochemical glucose sensors. The modified electrode was also applied to the determination of glucose in glucose injection solutions, and the satisfactory results obtained indicated that it was promising for the development of a novel non-enzymatic electrochemical glucose sensor. 2012 Elsevier B.V. All rights reserved.
语种英语
出版者ELSEVIER SCIENCE BV
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/88655]  
专题化学化工-已发表论文
推荐引用方式
GB/T 7714
Wu, Geng-huang,Song, Xin-hong,Wu, Yan-fan,et al. Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide[J]. http://dx.doi.org/10.1016/j.talanta.2012.10.066,2013.
APA Wu, Geng-huang.,Song, Xin-hong.,Wu, Yan-fan.,Chen, Xiao-mei.,Luo, Feng.,...&陈曦.(2013).Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide.http://dx.doi.org/10.1016/j.talanta.2012.10.066.
MLA Wu, Geng-huang,et al."Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide".http://dx.doi.org/10.1016/j.talanta.2012.10.066 (2013).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace