CORC  > 厦门大学  > 化学化工-已发表论文
Relationship between high-resolution computed tomography densitometry and audiometry in otosclerosis
Zhu, Mei-mei ; Sha, Yan ; Zhuang, Pei-yun ; Olszewski, Aleksandra E. ; Jiang, Jia-qi ; Xu, Jiang-hong ; Xu, Chen-mei ; Chen, Bing ; Sha Y(沙勇)
刊名http://dx.doi.org/10.1016/j.anl.2010.03.002
2010-12
关键词SENSORINEURAL HEARING-LOSS BONE-DENSITY MEASUREMENTS COCHLEAR OTOSCLEROSIS CT DENSITOMETRY CAPSULE DIAGNOSIS SCAN
英文摘要Objective: The aim of this study is to evaluate the usefulness of high-resolution computed tomography (HRCT) densitometry in the diagnosis of otosclerosis and to investigate the relationship between CT densitometry and audiometry. Methods: HRCT findings and audiometry were compared among 34 patients (34 ears, the otosclerosis group) with surgically confirmed otosclerosis between January 2007 and December 2007 and 33 patients (33 opposite normal ears, the control group) with facial paralysis diagnosed at the same period of time. Seven regions of interest (ROI) were set manually around the otic capsule on the axial slice of 0.75-mm-thick CT image. The mean CT values of these seven regions were measured. In each ROI, the mean CT value of the otosclerosis group and that of the control group were compared. Based on the CT findings, the ears with otosclerosis were classified into two groups: Group A showed no pathological CT findings; Group B showed low density around the cochlea. In the otosclerosis group, the relationship between the findings of CT and the results of audiometry was analyzed. Results: The mean CT values in the area posterior to the oval window and anterior to the oval window were significantly lower for the otosclerosis group compared with the control group (the former t = -2.030, p = 0.046; the latter Z = -4.979, p < 0.01). Group A consisted of 30 patients, 7 of which (23.33%) exhibited conductive hearing loss, and 23 of which (76.67%) exhibited mixed hearing loss; Group B had 4 patients, all with mixed hearing loss. For the otosclerosis group, the mean CT value in the area posterior to the oval window was positively correlated with the mean air conduction threshold (r = 0.4273, p = 0.0117) and with the mean air-bone gap (r = 0.3995, p = 0.0192). Conclusion: Quantitative evaluation of CT with slices less than 1 mm in thickness may provide important information for the diagnosis and assessment of otosclerosis which are unattainable through other methods. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
语种英语
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/62673]  
专题化学化工-已发表论文
推荐引用方式
GB/T 7714
Zhu, Mei-mei,Sha, Yan,Zhuang, Pei-yun,et al. Relationship between high-resolution computed tomography densitometry and audiometry in otosclerosis[J]. http://dx.doi.org/10.1016/j.anl.2010.03.002,2010.
APA Zhu, Mei-mei.,Sha, Yan.,Zhuang, Pei-yun.,Olszewski, Aleksandra E..,Jiang, Jia-qi.,...&沙勇.(2010).Relationship between high-resolution computed tomography densitometry and audiometry in otosclerosis.http://dx.doi.org/10.1016/j.anl.2010.03.002.
MLA Zhu, Mei-mei,et al."Relationship between high-resolution computed tomography densitometry and audiometry in otosclerosis".http://dx.doi.org/10.1016/j.anl.2010.03.002 (2010).