Calculation and usage of containment monitor radiation readings during PWR accidents
Li, J. ; Ye, Y. ; Shi, Z. ; Wang, J. ; Shi Z(施展)
2006
关键词containment radiation levels core damage assessment EAL
英文摘要A computer code named CALCON for calculation of containment monitor radiation readings is introduced. The validity of the code was verified by comparison with data given in IAEA technical documents. The contribution of isotopes to containment readings under conditions of core melt, gap release and normal coolant release were investigated. The conclusions were that the radiation reading in containment is mainly from iodine and noble gases when sprays are off, and the radiation reading is mainly from noble gases when sprays are on, and during the beginning hours when radionuclides are released into containment, the monitor readings will decrease rapidly. Curves of containment radiation readings versus shutdown time for DAYA BAY nuclear power plant were calculated using CALCON. (c) 2005 Elsevier B.V. All rights reserved.
语种英语
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/59559]  
专题材料学院-已发表论文
推荐引用方式
GB/T 7714
Li, J.,Ye, Y.,Shi, Z.,et al. Calculation and usage of containment monitor radiation readings during PWR accidents[J],2006.
APA Li, J.,Ye, Y.,Shi, Z.,Wang, J.,&施展.(2006).Calculation and usage of containment monitor radiation readings during PWR accidents..
MLA Li, J.,et al."Calculation and usage of containment monitor radiation readings during PWR accidents".(2006).
个性服务