CORC  > 集美大学
F-P标准具间距高精度测量
王秀琳 ; 黄文财 ; 谢建平
刊名http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=ldxu200306021&dbcode=CJFQ&dbname=CJFQ2003
2012-06-05 ; 2012-06-05
关键词F-P标准具 多光束干涉 光谱 F-P etalon multi-beam interference spectrum O439
其他题名High Precision Measurement of F-P Etalon Spacing
中文摘要提出一种通过测量F-P标准具透射峰移动个数与F-P标准具入射角度改变的对应关系,从而求得F-P标准具间距的高精度测量方法。当角度测量精度为30″,光谱仪精度为2 GHz时,该方法测量F-P标准具间距的相对误差为4×10-4; A high precision measure method of F-P etalon spacing is proposed by measuring the moving number of transmission resonant peak with the incident angle of F-P etalon. The measurement precision of this method shows that the relative error of F-P etalon spacing will be 4×10-4 when precision of angle is 30" and optical spectrum analyzer precision is 2 GHz.; 【作者单位】集美大学基础部; 中国科学技术大学物理系; 中国科学技术大学物理系 厦门 361021; 合肥 230026; 合肥 230026;【作者英文名】Wang Xiulin, Huang Wcncai, Xic Jianping(Basic Course Department, Jimei University, Xiamen 361021 China ; Department of Physics, University of Science & Technology of China, Hefei 230026 China
语种中文
内容类型期刊论文
源URL[http://ir.calis.edu.cn/hdl/235041/15956]  
专题集美大学
推荐引用方式
GB/T 7714
王秀琳,黄文财,谢建平. F-P标准具间距高精度测量[J]. http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=ldxu200306021&dbcode=CJFQ&dbname=CJFQ2003,2012, 2012.
APA 王秀琳,黄文财,&谢建平.(2012).F-P标准具间距高精度测量.http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=ldxu200306021&dbcode=CJFQ&dbname=CJFQ2003.
MLA 王秀琳,et al."F-P标准具间距高精度测量".http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=ldxu200306021&dbcode=CJFQ&dbname=CJFQ2003 (2012).