工业用蒸发式和水冷式冷凝器的循环水量和能耗研究 | |
张建一 ; 秘文涛 | |
刊名 | http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=dwyc200703018&dbcode=CJFQ&dbname=CJFQ2007
![]() |
2012-06-05 ; 2012-06-05 | |
关键词 | 蒸发式冷凝器 水冷式冷凝器 循环水量 能耗 Evaporative condenser Water-cooled condenser Water flow Energy consumption TQ051.5 |
其他题名 | Study of the water flow and energy consumption for evaporative and water-cooled condensers in industrial plants |
中文摘要 | 通过计算与现场测试,分析比较了蒸发式与水冷式冷凝器的循环水量和能耗。参照美国的经验数据,蒸发式冷凝器的循环水量约为立式水冷式的19%、约为卧式水冷式38%。现场测试发现,三种典型品牌蒸发式冷凝器的实际平均循环水量约为立式水冷式的51%、约为卧式水冷式的76%。三种典型品牌蒸发式冷凝器的单位排热量水泵能耗差异近一倍。它们的水泵平均能耗约为立式水冷式的46%、约为卧式水冷式的42%。实际运行中,蒸发式冷凝器的风机能耗占主导。; Water flow and energy consumption of evaporative and water-cooled condensers are analyzed by calculation and field test.Results show that water flow of evaporative condensers is approximately 19% of that for open condensers,and 38% of that for closed condensers,based on experimental data in the US.However,in practice,field tests show that the average water flow of three different brands of typical evaporative condensers is approximately 51% of that for open condensers and 76% of that for closed condensers.It is also found that the energy consumption of water pumps,in heat rejection per kW,may vary by a factor of two among three typical evaporative condensers.Their average energy consumption is approximately 46% of that of open condensers and 42% of that of closed condensers.In practice,the fan accounts for most of the energy consumption of evaporative condensers.; 【作者单位】集美大学机械工程学院; 集美大学机械工程学院 厦门361021; 厦门361021; 上海水产大学食品学院; 上海200090;【作者英文名】Zhang Jianyi1,Mi Wentao1,2 (1.College of Mechanical Engineering,Jimei University,Xiamen 361021,China;2.College of Food Science,Shanghai Fisheries University,Shanghai 200090,China) |
语种 | 中文 |
内容类型 | 期刊论文 |
源URL | [http://ir.calis.edu.cn/hdl/235041/14394] ![]() |
专题 | 集美大学 |
推荐引用方式 GB/T 7714 | 张建一,秘文涛. 工业用蒸发式和水冷式冷凝器的循环水量和能耗研究[J]. http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=dwyc200703018&dbcode=CJFQ&dbname=CJFQ2007,2012, 2012. |
APA | 张建一,&秘文涛.(2012).工业用蒸发式和水冷式冷凝器的循环水量和能耗研究.http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=dwyc200703018&dbcode=CJFQ&dbname=CJFQ2007. |
MLA | 张建一,et al."工业用蒸发式和水冷式冷凝器的循环水量和能耗研究".http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=dwyc200703018&dbcode=CJFQ&dbname=CJFQ2007 (2012). |