CORC  > 清华大学
水泥污秽区输电线路绝缘子选型建议
邢军 ; 刘洋 ; 梅红伟 ; 王黎明 ; XING Jun ; LIU Yang ; MEI Hongwei ; WANG Liming
2016-03-30 ; 2016-03-30
关键词水泥污秽 输电线路 绝缘子 选型 污闪事故 cement contamination transmission line insulator selection pollution flashover accidents TM216
其他题名Suggestions on Selection of Transmission Line Insulators for Cement Contamination Area
中文摘要笔者介绍了老工业基地徐州地区水泥污秽区输电线路各种类型绝缘子的运行特征,并结合生产实际对徐州电网110~500 kV输电线路绝缘子运行情况及特点进行了分析。同时,结合其他地区水泥污秽区绝缘子运行经验,提出了水泥污秽区绝缘子选型和运维的建议,以期减少水泥污秽区输电线路污闪事故的发生概率。; The operation characteristics of all kinds of transmission line insulators used in the cement contamination area of Xuzhou, an old industrial base, are introduced. According to actual condition of Xuzhou power grid, the operation situations and features of the 110 to 500 kV transmission line insulators are analyzed in detail. Some suggestions on selection and use of transmission line insulators are offered by considering the experiences of insulators operation in other cement polluted areas to reduce the probability of pollution flashover accidents of insulators.
语种中文 ; 中文
内容类型期刊论文
源URL[http://ir.lib.tsinghua.edu.cn/ir/item.do?handle=123456789/148223]  
专题清华大学
推荐引用方式
GB/T 7714
邢军,刘洋,梅红伟,等. 水泥污秽区输电线路绝缘子选型建议[J],2016, 2016.
APA 邢军.,刘洋.,梅红伟.,王黎明.,XING Jun.,...&WANG Liming.(2016).水泥污秽区输电线路绝缘子选型建议..
MLA 邢军,et al."水泥污秽区输电线路绝缘子选型建议".(2016).