CORC  > 清华大学
锅炉房水泵吸水高度及灌注水头高度探讨
池晓 ; 徐可培 ; 尹洪超 ; CHI Xiao ; XU Ke-pei ; YIN Hong-chao
2016-03-30 ; 2016-03-30
关键词水泵 汽蚀余量 灌注水头高度 吸水高度 吸水管路压降 Centre Georges Pompidou Form Linear elements TU991.35
其他题名The study of boiler water pump suction height and filling water head height
中文摘要通过模拟计算,描述水泵吸水口轴线与液面之间的相对位置受安装地的大气压、水温、水泵必须汽蚀余量、水泵吸水管路压降四方面因素影响。通过简述一个案例,介绍当采用大气式热力除氧器时,计算锅炉给水泵灌注水头高度需要考虑的因素。; Through numerical simulation,describes four aspects factors: the water pump water intake axis and the relative position between the liquid surface by the installation of atmospheric pressure,water temperature,NPSH,water pump suction pipe pressure drop. At the same time,this paper expounds a special case: the factors to be considered when use atmospheric type thermal deaerator of boiler feed pump to calculate the pump infusion water head height.
语种中文 ; 中文
内容类型期刊论文
源URL[http://ir.lib.tsinghua.edu.cn/ir/item.do?handle=123456789/144989]  
专题清华大学
推荐引用方式
GB/T 7714
池晓,徐可培,尹洪超,等. 锅炉房水泵吸水高度及灌注水头高度探讨[J],2016, 2016.
APA 池晓,徐可培,尹洪超,CHI Xiao,XU Ke-pei,&YIN Hong-chao.(2016).锅炉房水泵吸水高度及灌注水头高度探讨..
MLA 池晓,et al."锅炉房水泵吸水高度及灌注水头高度探讨".(2016).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace