船舶环形配电网电流保护加速动作方法研究
张芳 ; 毕大强 ; 曾祥君 ; 曾宪敏 ; Zhang Fang ; Bi Daqiang ; Zeng Xiangjun ; Zeng Xianmin
2016-03-30 ; 2016-03-30
关键词船舶 环形配电网 加速动作 STIPA goals directivity Q value sound field interference early and late acoustic energy ratio U665.12 TM773
其他题名Research on Accelerated Action Method of Current Protection for Shipboard Loop Power Distribution Systems
中文摘要在无通道保护方法的基础上,提出了一种适应于船舶环形配电网的电流保护加速动作的方法。该方法利用故障发生和线路一侧断路器跳闸引起的另一侧支路电流变化,和该变化所具有的时间特性来判断故障区间,来实现故障线路两端保护的相继速动。实例仿真分析验证了该方法的可行性。; This paper presents a new accelerated action method of current protection for the shipboard loop power distribution systems, which is based on the non-communication protection method. In the method, the changing of current through local relay is adopted when the fault occurs and the remote breaker of the line is triped, and the time characteristics of this changing are used to determine the fault zone, and then accelerated trip of the local break. The simulation analysis validates the feasibility of proposed protection method.