Suppression of common-mode and shaft voltages in inverter-driven induction motor | |
Zhong Yulin ; Zhao Zhengming ; Yuan Liqiang | |
2010-10-12 ; 2010-10-12 | |
关键词 | Practical Theoretical or Mathematical/ harmonics suppression induction motors passive filters PWM invertors/ common-mode voltages shaft voltages selective harmonics elimination pulse width modulation three-level neutral-point-clamped inverters induction motors passive common mode filter harmonics suppression frequency 40 Hz to 50 Hz/ B8310E Asynchronous machines B8360 Power convertors and power supplies to apparatus B8120L Power supply quality and harmonics/ frequency 4.0E+01 to 5.0E+01 Hz |
中文摘要 | A selective harmonics elimination pulse width modulation (SHEPWM) scheme was used to suppress common mode and shaft voltages in a three-level neutral-point-clamped inverter-driven induction motor system. A figure of merit for the harmonics was used to find the correct switching angles for the scheme. An improved SHEPWM which eliminates tripling order harmonics was used at 40-45 Hz, while the conventional SHEPWM was used at 45-50 Hz. The switching between the two modes at 45 Hz is very smooth. Together with a well-designed passive common mode filter, the harmonics eliminates scheme significantly reduces both the common mode voltage and the shaft voltage within the frequency range of interest. |
语种 | 中文 |
出版者 | Tsinghua University Press ; China |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/82459] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Zhong Yulin,Zhao Zhengming,Yuan Liqiang. Suppression of common-mode and shaft voltages in inverter-driven induction motor[J],2010, 2010. |
APA | Zhong Yulin,Zhao Zhengming,&Yuan Liqiang.(2010).Suppression of common-mode and shaft voltages in inverter-driven induction motor.. |
MLA | Zhong Yulin,et al."Suppression of common-mode and shaft voltages in inverter-driven induction motor".(2010). |