Estimation of axial dispersion in pulsed-plate extraction columns | |
Tang Xiaojin ; Chen Fei ; Luo Guangsheng ; Wang Jiading | |
2010-10-12 ; 2010-10-12 | |
关键词 | Axial dispersion Extraction column Mass transfer 2-PHASE FLOW MODEL Engineering, Chemical |
中文摘要 | In this study, a two-region physical model was used to quantitatively estimate axial dispersion in pulsed-plate extraction columns, considering the operating conditions, geometry parameters and the physical properties of the experimental system. The calculated results fit the experimental axial dispersion coefficients well in nine geometries of pulsed-plate columns. This model is of importance to the design and scale-up of pulsed-plate extraction columns. (C) 2009 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved. |
语种 | 英语 ; 英语 |
出版者 | INST CHEMICAL ENGINEERS ; RUGBY ; 165-189 RAILWAY TERRACE, DAVIS BLDG, RUGBY CV21 3HQ, ENGLAND |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/79436] ![]() |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Tang Xiaojin,Chen Fei,Luo Guangsheng,et al. Estimation of axial dispersion in pulsed-plate extraction columns[J],2010, 2010. |
APA | Tang Xiaojin,Chen Fei,Luo Guangsheng,&Wang Jiading.(2010).Estimation of axial dispersion in pulsed-plate extraction columns.. |
MLA | Tang Xiaojin,et al."Estimation of axial dispersion in pulsed-plate extraction columns".(2010). |