中文摘要 | 导线选型及排列是超高压输电技术的关键课题之一。本文阐述了相关的基本原理和限值标准,结合工程所采用的塔型和高海拔地区的特点,计算比较了各种导线型号及其排列方式对330 kV同塔双回输电线路产生的无线电干扰、可听噪声、地面电场、电晕损失等的影响,并提出了部分设计建议。; The selection and configuration of conductors is one of the basic and key problems for the design of the EHV transmission line.In this paper,the relevant principle is introduced.Based on the steel structure of the project and high altitude characteristic of northwest region of China,different schemes of conductor selection and configuration in such aspects as radio interference,audible noise,corona loss and electric field of the double circuit 330kV transmission line are compared in details. |