CORC  > 清华大学
ODSS软件对城市污水处理厂运行的模拟优化
沈勇 ; 汪诚文 ; 施汉昌 ; 张发鹏 ; SHEN Yong ; WANG Cheng-wen ; SHI Han-chang ; ZHANG Fa-peng
2010-06-10 ; 2010-06-10
关键词运行决策支持系统 城市污水处理厂 模拟优化 operation decision support system municipal WWTP simulation and optimization X703
其他题名Simulation and Optimization of WWTP Based on Operation Decision Support System
中文摘要利用基于污水处理模型的智能软件——城市污水处理厂运行决策支持系统(ODSS),对哈尔滨太平污水处理厂冬季运行情况进行了定量模拟优化,确定了好氧段水力停留时间和剩余污泥排放量,并对不同进水水质情况下的内回流比、污泥回流比和溶解氧浓度进行了模拟。结果显示,过渡段曝气长度宜控制在过渡段全长的80%左右,剩余污泥排放量宜控制在2000m3/d左右;对污泥回流比、内回流比和溶解氧浓度的控制可根据进水污染物浓度选取能源利用率最高的方案。; The quantitative simulation and optimization of operation of the Harbin Taiping WWTP in winter were carried out by using the intelligent software based on the wastewater treatment model,namely operation decision support system(ODSS) for municipal WWTP.The optimal aerobic HRT and discharge rate of excess sludge are determined,and the internal reflux ratio,sludge reflux ratio and DO concentration under different influent qualities were simulated.The results show that the aeration length of the transition stage should be limited to 80% of the total transition length.The discharge rate of excess sludge should be controlled at around 2 000 m3/d.As for the control of sludge reflux ratio,internal reflux ratio and DO concentration,a scheme achieving maximum energy utilization rate should be selected according to the influent pollutant concentration.
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/65962]  
专题清华大学
推荐引用方式
GB/T 7714
沈勇,汪诚文,施汉昌,等. ODSS软件对城市污水处理厂运行的模拟优化[J],2010, 2010.
APA 沈勇.,汪诚文.,施汉昌.,张发鹏.,SHEN Yong.,...&ZHANG Fa-peng.(2010).ODSS软件对城市污水处理厂运行的模拟优化..
MLA 沈勇,et al."ODSS软件对城市污水处理厂运行的模拟优化".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace