CORC  > 清华大学
化学混凝对两级曝气生物滤池出水的除磷效果研究
李伟伟 ; 高宝玉 ; 许春华 ; 卢佳 ; 邱继彩 ; 岳钦艳 ; LI Wei-wei ; GAO Bao-yu ; XU Chun-hua ; LU Jia ; QIU Ji-cai ; YUE Qin-yan
2010-06-10 ; 2010-06-10
关键词化学除磷 混凝 PFS PAM 中试 快滤池 chemical phosphorus removal coagulation PFS PAM pilot-scale test rapid filter X703
其他题名Study on Chemical Coagulation Process for Phosphorus Removal from Effluent of Two-stage Biological Aerated Filter
中文摘要为解决两级曝气生物滤池处理城市污水时除磷效果欠佳的问题,采用化学混凝工艺对其出水进行处理,以聚合硫酸铁(PFS)为絮凝剂,通过烧杯试验考察了PFS投量及助凝剂聚丙烯酰胺(PAM)对除磷效果的影响,并通过中试考察了混凝、沉淀、过滤工艺的除磷效果。结果表明,PAM的助凝作用并不明显,单独投加130 mg/L的PFS即可使出水TP<1 mg/L。在生物处理单元稳定运行的情况下,中试工艺的PFS投量在90~95 mg/L时可使出水TP<1 mg/L,总铁<0.5 mg/L。; To solve low phosphorus removal efficiency of two-stage biological aerated filter in treating municipal wastewater,the chemical coagulation process was used to treat its effluent.Polyferric sulfate(PFS) and polyacrylamide(PAM) were chosen as coagulant and coagulant aid respectively in jar tests,and the effects of dosages of PFS and PAM on chemical phosphorus removal were studied.The phosphorus removal efficiencies of coagulation,sedimentation and filtration processes were investigated through pilot-scale test.The results show that dosing PAM can not improve coagulation efficiency of PFS;the effluent TP is less than 1 mg/L when using PFS of 130 mg/L alone in jar tests.Under the condition of stable operation of the biological treatment unit,the effluent TP and total iron are less than 1 mg/L and 0.5 mg/L respectively when the dosage of PFS is 90-95 mg/L in the pilot-scale test.; 国家高技术研究发展计划(863)项目(2003AA601080)
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/65505]  
专题清华大学
推荐引用方式
GB/T 7714
李伟伟,高宝玉,许春华,等. 化学混凝对两级曝气生物滤池出水的除磷效果研究[J],2010, 2010.
APA 李伟伟.,高宝玉.,许春华.,卢佳.,邱继彩.,...&YUE Qin-yan.(2010).化学混凝对两级曝气生物滤池出水的除磷效果研究..
MLA 李伟伟,et al."化学混凝对两级曝气生物滤池出水的除磷效果研究".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace