中文摘要在中试水平上考察了3种不同开孔直径的穿孔曝气管(A:φ4mm,B:φ2mm,C:φ1mm)对一体式膜-生物反应器整体性能的影响.清水充氧性能试验表明,3种穿孔管条件下的反应器整体充氧性能基本一致;流态特性分析显示,3种穿孔管条件下的反应器流态均近似完全混合流.水动力学特性试验发现,升流区液体表观流速随着升流区曝气强度的增大呈现先上升后趋于稳定的现象,低曝气强度[<120m3/(m2·h)]时穿孔管A条件下的升流区液体表观流速最高,高曝气强度[>120m3/(m2·h)]时3种穿孔管条件下的升流区液体表观流速趋于一致(稳定值约为0.43m/s),恒通量膜过滤试验表明,穿孔管A条件下的跨膜压差上升速率(0.0382kPa/h)低于穿孔管C(0.05kPa/h).对本中试装置来说,开孔直径较大的穿孔管A的综合性能优于开孔直径较小的穿孔管B和C.; Effect of three perforated pipes with different orifice diameter (A:φ4mm, B:φ2mm, C:φ1mm) on the performance of a pilot-scale submerged membrane bioreactor(SMBR) was investigated. Oxygenation test with tap water showed that the overall oxygen transfer performance of the SMBR with three perforated pipes was nearly the same. Tracer pulse test indicated that the SMBR with three perforated pipes was close to continuous stirred tank reactor. Hydrodynamic test showed that superficial velocity in the riser rose firstly and then reached a steady value about 0.43m/s with aeration intensity in the riser; when aeration intensity was low [<120m3/(m2·h)], superficial velocity was higher under perforated pipe A; but when aeration intensity was high [>120m3/(m2·h)], the difference of superficial velocity among three perforated pipes became small. Filtration test under constant flux indicated that transmembrane pressure rising velocity with perforated pipe A (0.0382kPa/h) was lower than with perforated pipe C (0.05kPa/h). Perforated pipe A with bigger orifice diameter was superior to perforated pipe B and C with smaller orifice diameter in this pilot-scale SMBR.; 国家“863”项目(2002AA601220)
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/65322]  
专题清华大学
推荐引用方式
GB/T 7714
魏春海,汪诚文,黄霞,等. 曝气管开孔直径对一体式膜-生物反应器的影响[J],2010, 2010.
APA 魏春海,汪诚文,黄霞,WEI Chun-hai,WANG Cheng-wen,&HUANG Xia.(2010).曝气管开孔直径对一体式膜-生物反应器的影响..
MLA 魏春海,et al."曝气管开孔直径对一体式膜-生物反应器的影响".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace