曝气生物滤池最佳运行周期研究 | |
刘阳 ; 王劼 ; 白莹 ; 施汉昌 ; LIU Yang ; WANG Jie ; BAI Ying ; SHI Han-chang | |
2010-06-10 ; 2010-06-10 | |
关键词 | 曝气生物滤池 运行周期 反冲洗 biological aerated filter operation cycle backwashing X703 |
其他题名 | Optimum Operational Cycle of the Biological Aerated Filtrated Reactor |
中文摘要 | 以实际运行的污水处理厂为研究场地,通过对滤池压力、瞬时流量和滤池的纳污量的统计学回归分析,研究曝气生物滤池的运行周期。结果表明,滤池的运行周期可由滤池压力参数调控,滤池压力与瞬时流量和纳污量密切相关,一级滤池的压力公式为:P1=88.290+0.021Q+0.011X;二级滤池的压力公式为:P2=59.406+0.025Q+0.013X。; In order to determine the operation cycle of BAF,we use methods of testing pressure of filter, the instantaneous flow rate and the dirt amount intercepted by the filter media. The results indicated that the operation cycle is closely related to the pressure. The formula of the first level filter is P1=88.290 +0.021Q+0.011X and that of the second level filter is P1=59.406+0.025Q+0.013X. |
语种 | 中文 ; 中文 |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/64990] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | 刘阳,王劼,白莹,等. 曝气生物滤池最佳运行周期研究[J],2010, 2010. |
APA | 刘阳.,王劼.,白莹.,施汉昌.,LIU Yang.,...&SHI Han-chang.(2010).曝气生物滤池最佳运行周期研究.. |
MLA | 刘阳,et al."曝气生物滤池最佳运行周期研究".(2010). |