CORC  > 清华大学
CdZnTe个人剂量计能响特性的Monte Carlo模拟
康玺 ; 李君利 ; 曾志 ; 武祯 ; KANG Xi ; LI Junli ; ZENG Zhi ; WU Zhen
2010-06-10 ; 2010-06-10
关键词个人剂量计 能量响应 CdZnTe Monte Carlo方法 dosimeter energy response CdZnTe Monte Carlo method TL818
其他题名Monte Carlo simulations of the energy response of γ-ray dosimeters with CdZnTe semiconductor detectors
中文摘要为了获得合适的CdZnTe(CZT)个人剂量计的剂量-能量响应补偿方案,利用Monte Carlo程序MCNP4C对CZT、CZT加各种补偿物质和CZT在不同电子学下阀的剂量-能量响应特性进行了模拟计算。通过模拟得到了2种CZT个人剂量计剂量补偿方案:在CZT(5mm×5mm×5mm)前加15mm Pb(带有阶梯孔)和2mm Pb(带有孔面积为Pb截面面积3%的孔,并分高、低能两能量道计数)。为今后的CZT个人剂量计设计提供了理论依据。; A method was developed to compensate for the energy response of gamma-ray dosimeters with CdZnTe(CZT) semiconductor detectors by analyzing the energy response of different detector sizes,various shielding materials,and various electronic thresholds with MCNP4C.The simulations show that a 15 mm thick Pb shield with 12.5% holes placed before the CZT(5 mm�mm�mm) detector or a 2 mm thick Pb shield with 3% holes before the detector and counting in two energy channels provide effective energy response compensation.The results provide a theoretical guide for the further design of CZT dosimeter.; 国家自然科学基金资助项目(10575065)
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/63747]  
专题清华大学
推荐引用方式
GB/T 7714
康玺,李君利,曾志,等. CdZnTe个人剂量计能响特性的Monte Carlo模拟[J],2010, 2010.
APA 康玺.,李君利.,曾志.,武祯.,KANG Xi.,...&WU Zhen.(2010).CdZnTe个人剂量计能响特性的Monte Carlo模拟..
MLA 康玺,et al."CdZnTe个人剂量计能响特性的Monte Carlo模拟".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据