裂变产物~(94)Y和~(95)Y半衰期的测定 | |
王世联 ; 白涛 ; 师全林 ; 张小林 ; 凡金龙 ; 李奇 ; 刘杰 ; 卢嘉春 ; 常永福 ; WANG Shilian ; BAI Tao ; SHI Quanlin ; ZHANG Xiaolin ; FAN Jinlong ; LI Qi ; LIU Jie ; LU Jiachun ; CHANG Yongfu | |
2010-06-10 ; 2010-06-10 | |
关键词 | 半衰期 94Y 95Y 井式HPGe 质量归一 Half-life,94Y,95Y,Well-type HPGe,Mass normalization O571.3 |
其他题名 | Half-life determination of fission products ~(94)Y and ~(95)Y |
中文摘要 | 用脉冲反应堆热中子辐照浓缩235U溶液靶,经快速放射化学分离纯化出94Y和95Y溶液,稀释并制备放射性浓度依次相差~10倍的3个测量源。将测量源放置在井式HPGe探测器井内,采用质量归一法测得94Y和95Y的半衰期分别为(19.16±0.05)min和(10.36±0.03)min。; Solutions of enriched 235U were irradiated in thermal-neutron flux produced by a pulsed reactor,and 94Y and 95Y were separated chemically from the fission products immediately. The purified solution of 94Y and 95Y is diluted about ten times in sequence to three concentration solutions. Three sources were prepared with the solutions. The sources are measured,from the lower concentration to higher one,with a well-type HPGe detector to determine the half-life of 94Y and 95Y. The determined half-life results are (19.16�05) min and (10.35�04) min for94Y and 95Y,respectively. |
语种 | 中文 ; 中文 |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/63715] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | 王世联,白涛,师全林,等. 裂变产物~(94)Y和~(95)Y半衰期的测定[J],2010, 2010. |
APA | 王世联.,白涛.,师全林.,张小林.,凡金龙.,...&CHANG Yongfu.(2010).裂变产物~(94)Y和~(95)Y半衰期的测定.. |
MLA | 王世联,et al."裂变产物~(94)Y和~(95)Y半衰期的测定".(2010). |