非能动安注箱的设计与分析 | |
郑华 ; 臧希年 ; ZHENG Hua ; ZANG Xi-nian | |
2010-06-10 ; 2010-06-10 | |
关键词 | 非能动安注箱 CATHENA 流控设备 热工水力数值模拟 Passive SIT CATHENA fluidic device thermal-hydraulic numerical analysis TL421.1 |
其他题名 | Design and analysis of passive safety injection tank |
中文摘要 | 介绍了非能动安注箱的设计与实验,并用CATHENA程序分析其特性:注入流量的峰值,高注入流量的持续时间,最低注入流量等。计算结果表明非能动安注箱设计满足主要的性能要求,CATHENA程序计算结果与实验数据基本一致,可用于概念设计与事故分析。; The design and the test facility of passive safety injection tank are introduced. The code of CATHENA is used to analyse the characteristic of fluidic device: peak discharge flow rate, duration of high flow rate, minimum discharge flow rate. The calculated results show that the passive SIT meets its primary performance requirements. A comparison between the calculated results and the experimental data shows a good match, so CATHENA code can be used as a tool for conceptual design and accident analysis. |
语种 | 中文 ; 中文 |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/63213] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | 郑华,臧希年,ZHENG Hua,等. 非能动安注箱的设计与分析[J],2010, 2010. |
APA | 郑华,臧希年,ZHENG Hua,&ZANG Xi-nian.(2010).非能动安注箱的设计与分析.. |
MLA | 郑华,et al."非能动安注箱的设计与分析".(2010). |