中文摘要脆断是高电压复合绝缘子发生的应力腐蚀断裂现象,国内外的研究基本集中在"腐蚀"介质酸的来源上。为进一步探索脆断机理,从"应力"的角度,采用扫描电子显微镜和表面形貌测量仪研究了复合绝缘子芯棒因表面砂纸打磨痕迹等微裂纹引起的脆断,发现芯棒表面30~40μm的微裂纹在应力腐蚀环境下沿其方向向前发展。芯棒表面微裂纹尖端的应力强度因子增大,最终将导致裂纹尖端局部的损伤、萌生、演化扩展直至芯棒脆断,从而可以说明绝大多数绝缘子工作正常但极少数绝缘子发生脆断的现象。; Brittle fracture is a stress corrosion cracking phenomenon which occurs in high voltage composite insulators. Previous studies all focused on the source of the "corrosion" medium, e.g. the acid. This study focuses on the "stress" in a brittle fracture of fiber reinforced plastic (FRP) rod along a sand paper mark with observations using a scanning electron microscope and surface measurements. The results show that 30-40 μm micro-cracks caused by the sand paper on the surface of the FRP rod lead to stress corrosion crack propagating forward along the original sand paper mark direction. These micro-cracks augment the stress intensity factor on the local FRP rod surface in a corrosive environment, with the damage leading to initiation and propagation of cracks, and finally brittle fracture. The results explain why only a few insulators suffer from brittle fracture while many others have been safely used.; 国家杰出青年基金资助项目(50025720); 高等学校博士学科点专项科研基金资助项目(2000000315)
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/62707]  
专题清华大学
推荐引用方式
GB/T 7714
戴建军,梁曦东,姚学锋,等. 高电压复合绝缘子的脆断行为[J],2010, 2010.
APA 戴建军,梁曦东,姚学锋,DAI Jianjun,LIANG Xidong,&YAO Xuefeng.(2010).高电压复合绝缘子的脆断行为..
MLA 戴建军,et al."高电压复合绝缘子的脆断行为".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace