中文摘要某输水隧洞砼衬砌因温度应力引起裂缝,本文主要研究开裂后隧洞的承载能力,特别是一条隧洞运行另一条检修时的钢筋混凝土衬砌承载能力。并对可能的不利承载状况进行分析,以对工程安全运行进行综合评估。; The cracks of the reinforced concrete lining of tunnel is caused by thermal stress.The loading capacity of reinforced concrete lining after cracking is analyzed in this paper,especially under the conditions that one tunnel is in operation, the other is being checked.The purpose is to evaluate the project security by analyzing the possible outcomes.