其他题名ENERGY ANALYSIS OF COOL STORAGE AND DISCHARGING PROCESSES IN SOIL
中文摘要在对土壤蓄冷系统冷量损失过程分析的基础上,提出了地下埋管换热器垫层冷量损失与温差传热冷量损失的概念,并建立了垫层冷量损失和温差传热冷量损失的计算模型;为衡量系统在运行期间地下埋管换热器管束系统的运行效率,建立了埋管换热器管束系统的平均释冷率模型。通过理论研究与模拟计算,分析了土壤初始温度、埋管间距及管束结构对土壤蓄冷系统冷量损失的影响,指出了土壤蓄冷系统冷量损失随土壤初始温度及埋管间距之间的变化规律,为土壤蓄冷系统地下埋管换热器的优化设计提供理论依据。; Based on the analysis of the cool loss process of cool storage system in the soil,the concepts of underLayment cool loss and heat transferred cool loss were presented,and the calculated models of underlayment and heat transferred cool loss of underground heat exchangers were established.Moreover,in order to evaluate the operation efficieney of the buried pipe bundles,the average cool discharging factor model of the underground heat exchangers system was set up. Through the theoretical analysis and simulation,the influences of the initial soil temperature,pipe distance and pipe bun- dle structure on cool loss of the soil cool storage system were analyzed and the cool loss change rules with soil initial tem- perature and pipe distance were put forward,and these will provide theory proofs for the optimal design of underground heat exchangers of the soil cool storage system.; 国家自然科学基金(50378024)
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/52597]  
专题清华大学
推荐引用方式
GB/T 7714
余延顺,马最良,姚杨,等. 土壤蓄冷与释冷过程的能量分析[J],2010, 2010.
APA 余延顺.,马最良.,姚杨.,李先庭.,Yu Yanshun.,...&Li Xianting.(2010).土壤蓄冷与释冷过程的能量分析..
MLA 余延顺,et al."土壤蓄冷与释冷过程的能量分析".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace