高温除湿干燥机的实验和分析
陈军 ; 史琳 ; 张金龙 ; 张璧光 ; CHEN Jun ; SHI Lin ; ZHANG Jin-long ; ZHANG Bi-guang
2010-06-08 ; 2010-06-08
关键词除湿干燥机 分析 能耗分析 木材干燥 高温混合工质 dehumidifying heat pump, exergy analysis, energy analysis, lumber drying, high temperature mixed-refrigerant TS64
其他题名Exergy analysis and experiments on high temperature dehumidifying heat pump
中文摘要该文介绍了作者自行设计的高温除湿干燥机的特点,以及在木材干燥生产中的工业试验研究结果.该高温除湿干燥机利用清华大学研制的高温环保工质HTR01直接灌装R22制冷机组.除湿机出口风温可稳定达到86℃以上,能够与常规蒸汽干燥窑干燥工艺相匹配.除湿比能耗(SPC)在0.38~1.04之间.通过对试验结果的分析表明,减少压缩机损和压缩机入口管路的损可以提高设备的性能.; A high temperature dehumidifying heat pump designed by the authors was introduced. Using this device, our new refrigerant named THR01 under medium and high temperature conditions was tested. The out temperature could reach and keep over 86℃ and match with conventional vapor drying kiln. The specific power consumption is between 0.38 and 1.04. Based on the experimental data, exergy analysis shows that the performance of the heat pump is better and the exergy losses in the compressor and in the pipes of compressor entry are key factors influencing the exergy efficiency of the heat pump.