大型火力发电厂钢烟道结构的稳定性分析
李圣良 ; 石永久 ; 王元清 ; LI Sheng-liang ; SHI Yong-jiu ; WANG Yuan-qing
2010-06-07 ; 2010-06-07
关键词钢烟道 有限元 屈曲分析 设计建议 steel flue gas duct FEM eigen-buckling analysis suggestions for design TM621
其他题名Stability Analysis on Steel Flue Gas Duct in Large Thermal Power Plant
中文摘要针对目前大型火力发电厂烟道截面大、壁板较薄,易发生局部失稳的问题,以国内300 MW机组钢烟道为例,利用ANSYS软件,通过对7~21 m不同跨度、不设纵向加劲肋和设置纵向加劲肋的钢烟道进行屈曲研究,分析烟道壁板的屈曲模态,为防止钢烟道失稳提出设计建议.; The local buckling is a crucial point in the current projects of the steel flue gas duct for the unique characteristic of huge section with thin walls.In this paper,researches by ANSYS are carried out on a domestic project the steel flue gas duct of 300MW generating sets.The eigen-buckling analysis is conducted on the steel flue gas duct with span range from 7m to 21m to discuss the possible buckling modes;as well,different models with or without stiffening ribs are compared.Finally,some design suggestions for the steel flue gas duct are proposed.
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/46901]  
专题清华大学
推荐引用方式
GB/T 7714
李圣良,石永久,王元清,等. 大型火力发电厂钢烟道结构的稳定性分析[J],2010, 2010.
APA 李圣良,石永久,王元清,LI Sheng-liang,SHI Yong-jiu,&WANG Yuan-qing.(2010).大型火力发电厂钢烟道结构的稳定性分析..
MLA 李圣良,et al."大型火力发电厂钢烟道结构的稳定性分析".(2010).