基于ASTM C1202规范的混凝土抗氯离子渗透性测定仪的研制及应用
韩建国 ; 阎培渝 ; HAN Jian-guo ; YAN Pei-yu
2010-06-07 ; 2010-06-07
关键词混凝土 ASTMC1202规范 氯离子 抗渗透性 电量 concrete ASTM C1202 specification chlorine ion penetration resistance coulomb TU528
其他题名Development and application of concrete chlorine ion penetration resistance measuring instrument according to the ASTM C1202 specification
中文摘要基于ASTM C1202规范,研制了基于计算机USB总线的混凝土抗氯离子渗透性测定仪。该设备具有自动化程度和精度高、安全性强、可移植性和可扩展性强的特点。实验结果表明:随着混凝土水胶比的降低,其抗氯离子渗透性增强;同时,在相同的测试时间点,抗氯离子渗透性较高的混凝土试样端部盐池溶液的温升也较低。; Concrete chlorine ion penetration resistance measuring instrument based on the USB bus of computer system was developed according to the ASTM C1202 specification.Compared with the testing set given by the specification,this instrument has the characters of automation,high accuracy,security,transplantability and extensibility.Experiment results show that with the decrease of ratio of water to binder,the concrete chlorine ion penetration resistance is enhanced and that the salt solution temperature rise of concrete with higher chlorine ion penetration resistance is low with lower chlorine ion penetration resistance at the same testing time interval.; 西部交通建设科技项目(200131822370-(4))
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/46523]  
专题清华大学
推荐引用方式
GB/T 7714
韩建国,阎培渝,HAN Jian-guo,等. 基于ASTM C1202规范的混凝土抗氯离子渗透性测定仪的研制及应用[J],2010, 2010.
APA 韩建国,阎培渝,HAN Jian-guo,&YAN Pei-yu.(2010).基于ASTM C1202规范的混凝土抗氯离子渗透性测定仪的研制及应用..
MLA 韩建国,et al."基于ASTM C1202规范的混凝土抗氯离子渗透性测定仪的研制及应用".(2010).