CORC  > 清华大学
密实移动床离子交换柱的颗粒输送能力
梁栋 ; 景山 ; LIANG Dong ; JING Shan
2010-06-04 ; 2010-06-04
关键词密实移动床 离子交换柱 提升管 串液 无阀操作 moving-bed column ion exchange riser liquid leakage non-mechanical valve TQ051.1
其他题名Particles Transport Velocity in a Moving-bed Column for Ion Exchange Resin
中文摘要实验研究了工业上可用于从高放射性溶液中去除铯离子的f280 mm密实移动床离子交换柱的颗粒输送能力及其影响因素. 实验结果表明,密实移动床的进液量、提升液表观操作流速和密实移动床中的交换剂高度是影响固体颗粒提升速率的因素,并从压力平衡的角度对实验现象进行了解释. 根据实验结果,对这些影响因素进行了无因次关联. 在本实验中,斜管内串液量保持恒定,串液的方向是由提升管流进离子交换柱底部,这说明细长斜管可以有效地减小串液量.; The particles transport velocity and influencing factors for a f280 mm moving-bed column, which is possibly used in industry for removing 137Cs ions from the highly radioactive solution, are investigated. Experimental results show that the feeding rate of liquid into the moving-bed column, liquid rising velocity of riser and height of particles in the moving-bed column have important influence on particles transport velocity, and the reason is given to the system pressure balance. Based on the data, the dimensionless correlation has been obtained for particles transport velocity. Experimental results also show that the leakage rate of liquid through the solid-return pipe remains constant and the direction of liquid leakage is from riser to downer due to the relatively thin and long solid-return pipe.; 国家863计划资助项目(编号:2003AA518020)
语种中文 ; 中文
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/36150]  
专题清华大学
推荐引用方式
GB/T 7714
梁栋,景山,LIANG Dong,等. 密实移动床离子交换柱的颗粒输送能力[J],2010, 2010.
APA 梁栋,景山,LIANG Dong,&JING Shan.(2010).密实移动床离子交换柱的颗粒输送能力..
MLA 梁栋,et al."密实移动床离子交换柱的颗粒输送能力".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace