CORC  > 清华大学
A two-dimensional CVIB imaging system with a speckle tracking algorithm
Bai, Jing ; Liu, Ke ; Jiang, Yong ; Ying, Kui ; Zhang, Pengfei ; Shao, Jinhua
2010-05-11 ; 2010-05-11
关键词myocardial ischemia cyclic variation in integrated backscatter integrated backscatter speckle tracking ultrasound ULTRASONIC TISSUE CHARACTERIZATION MYOCARDIAL INTEGRATED BACKSCATTER CYCLIC VARIATION WALL THICKNESS CARDIAC CYCLE IN-VIVO ISCHEMIA ECHOCARDIOGRAPHY ELASTOGRAPHY REPERFUSION Acoustics Radiology, Nuclear Medicine & Medical Imaging
中文摘要Quantitative ultrasound tissue characterization based on integrated backscatter (IB) has shown great potential in detecting myocardial ischemia. The magnitude of the cyclic variation in IB (CVIB) has been considered one promising parameter in assessing regional myocardial contractile performance. This lab has previously developed a novel ultrasonic fusion imaging method based on CVIB. However, the major problem for clinical applications of this technique is that the myocardial tissue could not be tracked effectively without cardiologist's intervention. This paper introduced a speckle tracking method into the CVIB-weighted imaging system, called speckle tracking algorithm with adaptive window size (STAWAWS), to track myocardial tissue particle automatically. This method provides a way to obtain the particle's positions frame by frame in a series of B-mode images. Then using the RF signals according to the particle's positions the IB curve can be calculated to produce CVIB value. The method was applied on the experimental and clinical data cases's analysis. The results of dog's data processing showed that this method could eliminate the misunderstanding of myocardial ischemia especially near the endocardium. The results of clinical data suggested that this method had clinical significance in detecting ischemic myocardium. Though the CVIB-weighted images obtained by the use of this auto-tracking method can improve the accuracy of detecting myocardial ischemia, it is not real-time analysis and the clinical data cases are not sufficient. Further clinical validation is still needed in the future' work. (C) 2008 Elsevier B.V. All rights reserved.
语种英语 ; 英语
出版者ELSEVIER SCIENCE BV ; AMSTERDAM ; PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/27672]  
专题清华大学
推荐引用方式
GB/T 7714
Bai, Jing,Liu, Ke,Jiang, Yong,et al. A two-dimensional CVIB imaging system with a speckle tracking algorithm[J],2010, 2010.
APA Bai, Jing,Liu, Ke,Jiang, Yong,Ying, Kui,Zhang, Pengfei,&Shao, Jinhua.(2010).A two-dimensional CVIB imaging system with a speckle tracking algorithm..
MLA Bai, Jing,et al."A two-dimensional CVIB imaging system with a speckle tracking algorithm".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace